English
THE PUSH LEVER AND TRIGGER MUST MOVE SMOOTHLY. Trigger
| Do not connect |
Push lever | air hose |
(2) Adjust the air pressure to 70 psi (4.9 bar | 5 kgf/cm2). |
Connect the air hose. |
|
Do not load any nails in the Nailer. |
|
Set the switching device to the upward position (SINGLE SEQUENTIAL ACTUATION MECHANISM).
(Set the switching device to the upward position completely as shown in the diagram. Otherwise, it will not operate properly.)
Upward position
Switching Device
THE NAILER MUST NOT LEAK AIR.
(3)Remove the finger from the trigger and press the push lever against the wood.
THE NAILER MUST NOT OPERATE.
Depress push lever | Do not pull trigger |
|
14