English

Working environment

WARNING

No flammable gas, liquid or other flammable objects at worksite.

Clear the area of children or unauthorized personnel.

Air supply

DANGER

NEVER

use

oxygen or

other

bottled

gases.

Explosion

may

occur.

 

WARNING

Never connect Nailer to pressure which potentially exceeds 200 psi (13.7 bar 14 kgf/cm2).

Never use non relieving coupler on Nailer.

1.Power source

Use only clean, dry, regulated compressed air as a power source for this Nailer.

Aircompressorsusedtosupplycompressed air to this Nailer must comply with the requirements of the latest version of ANSI Standard B 19.3 “Safety Standard For Compressors For Process Industries.”

Moisture or oil in the air compressor may accelerate wear and corrosion in the Nailer.

Drain daily.

2.Filter-Regulator-Lubricator

Use a regulator with a pressure range of 0 –

120 psi (0 – 8.3 bar 0 – 8.5 kgf/cm2).

Filter-regulator-lubricator units supply an optimum condition for the Nailer and extend the Nailer life. These units should always be

used.

 

 

 

 

Filter

filter

removes moisture

and

The

dirt

mixed

in

compressed

air.

Drain daily unless fitted with an automatic drain.

Keep the filter clean by regular maintenance.

Regulator

The regulator controls the operating pressure for safe operation of the Nailer. Inspect the regulator before operation to be sure it operates properly.

Lubricator

The lubricator supplies an oil mist to the Nailer.

Inspect the lubricator before operation to be sure the supply of lubricant is adequate. Use Hitachi pneumatic tool lubricant.

 

 

 

Regulator

 

Nailer Side

 

 

Compressor

 

 

 

 

Side

 

 

 

Lubricator

Filter

 

3.

Air hose

 

 

 

 

 

 

 

Air hose must have a minimum working

 

pressure rating of 150 psi (10.4 bar 10.6

 

kgf/cm2) or 150% of the maximum pressure

 

produced in the system, whichever is

4.

higher.

 

 

 

 

Air consumption

 

 

 

 

Using the Air consumption table and the

 

Air compressor size formula, find a correct

 

compressor size.

 

 

 

 

Air consumption table

 

 

 

 

Operating

psi

80

90

100

 

(bar)

(5.5)

(6.2)

(6.9)

 

pressure

 

(kgf/cm2)

(5.6)

(6.3)

(7)

 

 

 

Air

ft3/cycle

.038

.042

.045

consumption

(ltr/cycle) (1.07) (1.18) (1.29)

 

Air compressor size formula

 

 

Amount of air required

 

 

 

= number of Nailers

 

 

 

× average nails driven each minute

 

per Nailer

 

 

 

 

× air consumption at given air

 

pressure

 

 

 

 

× safety factor (always 1.2)

 

 

Example: 3 Nailers operating at 100 psi

 

driving 30 nails per minute

 

 

Amount of air required

1.2

 

 

= 3 30 .045 (1.29)

 

 

= 4.9 CFM (ft3/min) (139 ltr/min)

9