CHAPTER 3 WIRING, CONNECTION

3.2 CONNECTION TO PROGRAMABLE CONTROLLER

In case of operating this unit connecting to programable controller, there are 4 patterns of input terminals (Table 3-2a), 2 patterns of output terminals(Table 3-2b). Please connect fitted to the type of programable controller used.

Table 3-2a Connection of Input terminal (Dn, STRB, CM1) to Programable controller

Sink logic

Source logic

In case of using internal interface power source

In case of using internal interface power source

S

 

COM

P24B

 

P24B

 

 

 

 

 

 

 

Short

DC24V

Short

PLCB

DC24V

PLCB

 

 

Circuit

 

Circuit

CM1

 

 

CM1

 

 

 

 

 

 

 

Dn

Dn

 

 

 

STRB

STRB

 

 

COM

 

S

 

 

 

 

 

 

YTR48 type

SJ-DG

YTS48 type

 

 

Output module

SJ-DG

 

 

Output module

 

 

 

 

In case of using external power source

In case of using external power source

S

P24

COM

P24

 

DC24

PLCB

 

 

 

DC24V

 

PLC

DC24

 

 

CM1

 

 

CM1

 

 

 

 

Dn

 

Dn

 

 

STRB

 

 

 

 

DC24V

STRB

 

 

COM

 

 

 

 

S

 

 

 

 

 

 

YTR48 type

SJ-DG

YTS48 type

 

 

Output module

 

 

 

SJ-DG

 

 

 

Output module

 

 

 

 

 

Table 3-2b Connection of output terminal(SEQ￿CMB) to programable controller

Sink logic

Source logic

4

Page 10
Image 10
Hitachi SJ-DG instruction manual Connection to Programable Controller, Case of using external power source