Hitachi SJ-DG instruction manual TWO Dividing Binary Input, Bin Div

Models: SJ-DG

1 20
Download 20 pages 19.71 Kb
Page 16
Image 16

CHAPTER 5 FUNCTION

D15 D14 D13 D12 D11 D10 D 9 D 8 D 7 D 6 D 5 D 4 D 3 D 2 D 1 D 0

0

0

1

1

0

0

 

 

 

 

0

0

0

0

0

0

0

0

0

 

 

 

0

Setting data 4

Setting data 3

Setting data 2

Setting data 1

Precaution Refer to 5.3 ”DATA INPUT TIMING” for signal input timing.

5.1.3 TWO DIVIDING BINARY INPUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting of dip switch TYPE

 

It is possible to change setting data by twice input of data, higher data and lower data. And it is possible to select frequency setting, torque limit setting, acceleration and deceleration time setting or position setting by change of classification code (Refer to Figure 5.2 Table of classification code.). Setting resolution can be selected by rotary switch CODE.

Figure 5.1.3 shows data bit construction of the input binary data divided into two.

12

BIN DIV

(Higher)

(Lower)

D15

D14 D13 D12 D11 D10

D 9

D 8

D 7

D 6

D 5

D 4

D 3

D 2

D 1

D 0

Higher or Lower classification code

Setting data of higher 8bits or lower 8 bints

Figure 5.1.3 Data bit construction of the input binary data divided into two

(Example of setting) In case of setting frequency to resolution 0.01Hz (Setting of rotary switch CODE --- 0, 1, 2￿￿

(1)Converse value which 60 multiply 100 to 16 bits binary value. And then input higher 8 bits to D7 to D0 terminal, higher code of setting frequency to D15 to D8 terminal.

60×100 = 6000 ￿ 0001011101110000 (Binary)

D15

D14

D13

D12

D11

D10

D 9

D 8

D 7

D 6

D 5

D 4

D 3

D 2

D 1

D 0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

0

0

0

0

0

0

0

0

1

0

1

0

1

1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Higher code setting frequency

Higher 8 bits setting data

(2)When data input is definite, turn strobe signal on.

(3)Turn strobe signal off.

(4)Input remaining data, lower 8 bits to D7 to D0 terminal, and D15 to D8terminal to lower code of setting

D15 D14 D13 D12 D11 D10 D 9 D 8 D 7 D 6 D 5 D 4 D 3 D 2 D 1 D 0

0

0

0

0

0

0

0

1

0

1

1

1

0

 

 

 

 

0

0

0

 

 

 

Lower code setting frequency

Lower 8 bits setting data

frequency.

(5)When data input is definite, turn strobe signal on.

(6)Turn strobe signal off.

Precaution Refer to 5.3 ”DATA INPUT TIMING” for signal input timing.

10

Page 16
Image 16
Hitachi SJ-DG instruction manual TWO Dividing Binary Input, Bin Div