Func.

 

 

Default

Set

Name / Description

Value

Code

Value

 

 

–FE(F)/–FU

 

 

 

 

 

 

 

 

 

 

 

 

B095

Dynamic braking control

00

 

 

• 00 Disable

 

 

 

 

• 01 Enable during RUN only

 

 

 

• 02 Enable always

 

 

 

 

 

 

 

B096

Dynamic braking activation level

360 / 720

 

 

 

 

 

B130

Over-voltage LADSTOP enable

00

 

 

• 00 Disable

• 01 Enable

 

 

 

 

 

 

B131

Over-voltage LADSTOP level

380 / 760

 

 

 

 

 

B140

Over-current trip suppression

00

 

 

• 00 Disable

• 01 Enable

 

 

 

 

 

 

 

B150

Carrier mode

 

00

 

 

• 00 Disable

• 01 Enable

 

 

 

 

 

 

 

B151

Quick-start enable

 

00

 

 

• 00 Disable

• 01 Enable

 

 

 

 

 

 

 

“C” Group: Intelligent Terminal Functions

Func.

 

 

Default

Set

Name / Description

Value

Code

Value

 

 

–FE(F)/–FU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C001/

Terminal [1] function

Twenty-four option

00

 

C201

 

codes available

 

 

 

 

(see page 28)

 

 

C002/

Terminal [2] function

01

 

 

 

C202

 

 

 

 

 

 

 

 

 

C003/

Terminal [3] function

 

02 / 16

 

C203

 

 

 

 

 

 

 

 

 

C004/

Terminal [4] function

 

03 / 13

 

C204

 

 

 

 

 

 

 

 

 

C005/

Terminal [5] function

 

18 / 09

 

C205

 

 

 

 

 

 

 

 

 

C006/

Terminal [6] function

 

09 / 18

 

C206

 

 

 

 

 

 

 

 

 

24

Page 26
Image 26