Parameter tables for user-settable functions follow these conventions:

Some parameters have 2nd motor equivalents, indicated by the x2xx parameter codes in the left-most column.

Some parameters specify an option code. Where applicable, the options codes will be in a bulleted list in the Name/Description column.

The default values apply to all models unless otherwise noted for each parameter... –FE(F) (Europe) / – FU (U.S.)

Some parameters cannot be edited during Run Mode, and certain Software Lock settings (B031) can prohibit all edits. If in doubt, place the inverter in Stop Mode or consult the inverter manual for details.

“F” Group: Main Profile Parameters

Func.

 

Name / Description

Default

Set

Code

 

Value

Value

 

 

 

 

 

 

 

 

 

 

F001

Output frequency setting

0.0

 

 

 

 

 

F002

Acceleration (1) time setting

10.0

 

 

 

 

 

F202

Acceleration (1) time setting, 2nd motor

10.0

 

 

 

 

 

F003

Deceleration (1) time setting

10.0

 

 

 

 

 

F203

Deceleration (1) time setting, 2nd motor

10.0

 

 

 

 

 

F004

Keypad Run key routing

00

 

 

• 00 Forward

• 01 Reverse

 

 

 

 

 

 

 

“A” Group: Standard Functions

Func.

 

Default

Set

Name / Description

Value

Code

Value

 

–FE(F)/–FU

 

 

 

 

 

 

 

 

 

 

 

A001/

Frequency source setting

01 / 00

 

A201

• 00 Keypad potentiometer

 

 

 

• 01 Control terminal

 

 

 

• 02 Function F001 setting

 

 

 

• 03 ModBus network input

 

 

 

• 10 Calculate function input

 

 

 

 

 

 

A002/

Run command source setting

01 / 02

 

A202

• 01 Input terminal FW or RV (assignable)

 

 

 

• 02 Run key on keypad, or digital operator

 

 

 

• 03 ModBus network input

 

 

 

 

 

 

18