Hitachi SJ2002 manual Wire Connectors, Fuse and Circuit Breaker Sizes

Models: SJ2002

1 34
Download 34 pages 41.24 Kb
Page 5
Image 5

 

Wire Size

Torque Range

Terminal Connector

Range

 

 

 

(AWG)

ft-lbs

(N-m)

 

 

 

 

 

 

 

 

Logic/Analog connector

30—16

0.16—0.19

0.22—0.25

 

 

 

 

Relay connector

30—14

0.37—0.44

0.5—0.6

 

 

 

 

Wire Connectors

Warning: Field wiring connections must be made by a UL Listed and CSA Certified ring lug terminal connector sized for the wire gauge being used. The connector must be fixed using the crimping tool specified by the con- nector manufacturer.

Terminal (ring lug)

Cable support

Cable

Fuse and Circuit Breaker Sizes

The inverter’s input power wiring must include UL Listed, dual-element, 600V fuses, or UL Listed, inverse-time, 600V circuit breakers.

200V Models

Motor output

Inverter Model

Ampere Rating for

 

 

kW

HP

 

Fuse or Breaker

 

 

 

 

 

 

 

 

 

 

0.2

1/4

–002NFE(F)2/NFU2

10

 

 

 

 

0.4

1/2

–004NFE(F)2/NFU2

10

 

 

 

 

0.55

3/4

–005NFE(F)2

10

 

 

 

 

0.75

1

–007NFE(F)2/NFU2

15

 

 

 

 

1.1

1 1/2

–011NFE(F)2

15

 

 

 

 

1.5

2

–015NFE(F)2/NFU2

20 (single ph.)

 

 

 

15 (three ph.)

 

 

 

 

2.2

3

–022NFE(F)2/NFU2

30 (single ph.)

 

 

 

20 (three ph.)

 

 

 

 

3.7

5

–037LFU2

30

 

 

 

 

5.5

7 1/2

–055LFU2

40

 

 

 

 

7.5

10

–075LFU2

50

 

 

 

 

3