Hearth & Home Technologies • BV4236DBI, BV4842DBI • 2209-900 Rev. N • 9/1232
F. WallSwitchInstallationforFan(Optional)
If the box is being wired to a wall mounted switch for use
with a fan (See Figure 12.3):
• The power supply for the appliance must be brought into
a switch box.
• The power can then be supplied from the switch box
to the appliance using a minimum of 14-3 with ground
wire.
• At the switch box connect the black (hot) wire and red
(switch leg) wire to the wall switch as shown.
• At the appliance connect the black (hot), white (neutral)
and green (ground) wires to the junction box as
shown.
• Add a 1/4 in. insulated female connector to the red
(switch leg) wire, route it through the knockout in the face
of the junction box, and connect to the top fan switch
connector (1/4 in. male) as shown.
Red
Switch
Switch Box
Red
Black
Black
Green Green
White
Power
Supply
Wires
White
Red
Black
Green
White
Minimum 14-3 AWG
with Ground
Junction Box
Knockout
Figure12.3JunctionBoxWiredtoWallSwitchorBC10
G.ControlModuleOperation
1. The control module has an ON/OFF/REMOTE selector
switch that must be set. See Figure 12.4.
OFF Position: Appliance will ignore all power inputs and
will not respond to any commands from a wall switch or
remote. The unit should be in the OFF position during
installation, service, battery installation, and in the event
that the control goes into LOCK-OUT mode as a result
of an error code.
ON Position: Appliance will ignite and run continuously
in the HI ame setting, with no adjustment in ame
output. This mode of operation is primarily used for
initial installation or power outage operation with battery
backup.
REMOTE Position: Appliance will initiate commands
from a wired wall switch and/or one of the optional
wireless remote options.
2. A wall switch can be wired into the control module brown
and red wires. See Figure 12.1.
Figure12.4ControlModule
NG/LP SETTING
STATUS INDICATOR LED
SELECTOR
SWITCH
FLAME HI/LO SWITCH
(RC100 OR WIRED WALL SWITCH ONLY)
3. If using a wired wall switch with the module in REMOTE
mode, the ame output can be adjusted with the HI/LO
selector switch on the module. See Figure 12.4. Note
that the ame HI/LO selector switch will become inactive
once an optional remote control (RC200/RC300) is
programmed to the control module. Note that the control
module will always ignite the replace on HI and remain
so for the initial 10 seconds of operation. If the HI/LO
is switched to the LO position, the ame output will
automatically drop to the lowest setting after the ame
has been established for 10 sec. After this 10 second
period, the ame can be adjusted from HI to LO with
the switch.
4. The control module has safety feature that automatically
shuts down the replace after 9 hours of continuous
operation without receiving a command from the
remote.
5. If you intend to use both a wired wall switch and an
optional wireless wall switch to operate your replace,
the wall switch will override any commands given by
the remote.
6. The module has the capability to recognize potential
malfunctions. If these occur, it will fail to ignite and/or
respond to a command to ignite via the wall switch and/
or remote. In this case, the module may have gone
into LOCK-OUT mode. In this state, it will emit a RED/
GREEN LED error code. To reset the error code, switch
the selector to OFF, and then back to REMOTE or ON.
If the ignition command again fails, the module will emit
an LED error code, prior to going back into LOCK-OUT
mode. Contact your dealer for service if this occurs.
NineHourSafetyShutdownFeature
This appliance has a safety feature that automatically
shuts down the replace after 9 hours of continuous
operation without receiving a command from the
remote.