Hearth & Home Technologies • BV4236DBI, BV4842DBI • 2209-900 Rev. N • 9/1230

A. WiringRequirements

NOTICE: This appliance must be electrically wired
and grounded in accordance with local codes or, in the
absence of local codes, with Nationa l Electric C ode
ANSI/NFPA70-latestedition or the CanadianElectric
CodeCSAC22.1.
• Wire the appliance junction box to 110-120 VAC. This is
required for proper operation of the appliance ( IntelliFire
Plus™ ignition).
• A 110-120 VAC circuit for this product must be protected
with ground-fault circuit-interrupter protection, in compli-
ance with the applicable electrical codes, when it is installed
in locations such as in bathrooms or near sinks.
• Low voltage and 110 VAC voltage cannot be shared
within the same wall box.
WARNING! Risk of Shock or Explosion! DO NOT wire
110V to the valve or to the appliance wall switch. Incorrect
wiring will damage controls.

B. IntelliFirePlus™IgnitionSystemWiring

• Wire the appliance junction box to 110 VAC for proper
operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT wire
IPI controlled appliance junction box to a switched circuit.
Incorrect wiring will override IPI safety lockout.
• Refer to Figure 12.1, IntelliFire Plus™ Pilot Ignition (IPI)
Wiring Diagram.
• This appliance is equipped with an IntelliFire Plus™
control valve which operates on a 6 volt system.
• Plug the 6 volt transformer plug into the appliance junction
box to supply power to the unit OR install four AA cell
batteries (not included) into the battery pack before use.

C. OptionalAccessoriesRequirements

• This appliance may be used with a wall switch, wall
mounted thermostat and/or a remote control.
Wiring for optional Hearth & Home Technologies approved
accessories should be done now to avoid reconstruction.
Follow instructions that come with those accessories.
• Hearth & Home Technologies recommends that Intel-
liFire Plus™ wireless controls be used for their features
and functionality with the IntelliFire Plus™ ignition sys-
tem.
• A standard ON/OFF switch is compatible.
12 ElectricalInformation 