Hearth & Home Technologies • BV4236DBI, BV4842DBI • 2209-900 Rev. N • 9/1220
5 FramingandClearances 
A. SelectingApplianceLocation
When selecting a location for the appliance it is important to
consider the required clearances to walls (see Figure 5.1).
WARNING! Risk of Fire or Burns! Provide adequate
clearance around air openings and for service access.
Due to high temperatures, the appliance should be locat-
ed out of trafc and away from furniture and draperies.
NOTICE: Illustrations reect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams
are not drawn to scale. Actual installation may vary due to
individual design preference.
Figure5.1ApplianceLocations
A
B
B
B
C
D
E
TOP VENT
TOP VENT
ALCOVE
INSTALLATION
TOP VENT
A
F
BV4236DBI A BCDE F
Inches 51 42 72 See Mantel
Projections
22 1/2
Millimeters 1295 1067 1829 559 13
BV4842DBI A BCDE F
Inches 55-7/8 49 79 See Mantel
Projections
22 1/2
Millimeters 1419 1245 2007 559 13