Hearth & Home Technologies • BV4236DBI, BV4842DBI • 2209-900 Rev. N • 9/1216
NG LP
BV4236DBI
BV4842DBI
NOTCH LOCATION
BURNER BOTTOM
Figure3.5BurnerIdentication
D. BurnerIdentication/Verication
The burner may be accessed for identication and verication purposes. This task should be performed by a qualied ser-
vice technician. The base refractory, valve plate, optional refractory and grate do not need to be removed to access the
burner assembly. The logs and ber burner top need to be removed to access the burner. Disconnect the pilot from the
burner before removal. See Figure 3.5 for burner identication chart. Notch patterns are located on bottom side of burner.