THIS IS A STATE WHERE THE PUSH LEVER STOPPER RAN INTO THE UPPER PART OF THE PUSH LEVER AND THE PUSH LEVER CANNOT BE PUSHED UP.

Push Lever Stopper

Push Lever

THE PUSH LEVER AND TRIGGER MUST MOVE SMOOTHLY.

Trigger

English

Do not pull Trigger

Keep the Nail Feeder

(B) pulled backward.

Nail Feeder (B)

Depress Push Lever

(4)Separate the push lever from the wood.

Next, point the nailer downward, pull the trigger and then wait in that position for 5 seconds or longer.

 THE NAILER MUST NOT OPERATE.

Push Lever

Keep the Nail Feeder (B) pulled

Pull Trigger

backward. Do not connect air hose

Nail Feeder (B)

(2)Adjust the air pressure to 70 psi (4.9 bars 5 kgf/cm2). Connect the air hose.

Do not load any nails in the Nailer.

Set the switching device to the upward position

(SINGLE ACTUATION MECHANISM).

(Set the switching device to the upward position completely as shown in the diagram. Otherwise, it will not operate properly.)

Upward position

Switching Device

THE NAILER MUST NOT LEAK AIR.

(3)Remove the finger from the trigger and press the push lever against the wood.

THE NAILER MUST NOT OPERATE.

(5)1 Pull the Nail Feeder (B) backward, and without touching the trigger, depress the push lever against the workpiece.

Pull the trigger.

THE NAILER MUST OPERATE.

2Hold the trigger back while separating the push lever from the wood.

The nailer will remain in operated status (the driver blade will remain at the bottom).

3Remove the finger from the trigger.

Nailer operation will end (the driver blade will return to the top).

(6)Set the switching device to the downward position

(CONTACT ACTUATION MECHANISM).

(Set the switching device to the downward position completely as shown in the diagram. Otherwise, it will not operate properly.)

Switching Device

Downward position

— 11 —