Hitachi Koki USA NR 90AC3 manual Action WHY HOW, Problem Check Method Correction

Models: NR 90AC3

1 56
Download 56 pages 11.48 Kb
Page 18
Image 18

English

Maintenance chart

ACTION

WHY

HOW

 

 

 

Drain air line filter daily.

Prevent accumulation of moisture

Open manual petcock.

 

and dirt.

 

 

 

 

Keep lubricator filled.

Keep the Nailer lubricated.

Fill with Hitachi pneumatic tool

 

 

lubricant.

 

 

 

Clean filter element — then blow

Prevent clogging of filter with dirt.

Follow manufacturer’s instructions.

air through filter in direction

 

 

opposite to normal flow.

 

 

 

 

 

Clean magazine and feeder

Prevent a jam.

Blow clean daily.

mechanism.

 

 

 

 

 

Keep push lever working properly.

Promote operator safety and

Blow clean daily.

 

efficient Nailer operation.

 

 

 

 

Lubricate the Nailer after nailing.

Extend the Nailer life.

Supply 5 – 10 drops of lubricant

 

 

into the Nailer.

 

 

 

Drain air compressor.

Keep the Nailer operated properly.

Open petcock on air compressor tank.

 

 

 

Operator troubleshooting

Most minor problems can be resolved quickly and easily using the table below. If problems persist, contact a Hitachi authorized service center for assistance.

PROBLEM

CHECK METHOD

CORRECTION

Nailer operates, but no nail is driven.

Check for a jam.

Clear a jam.

 

 

 

 

Check function of nail feeder per

Clean and lubricate.

 

page 17.

 

 

 

 

 

Ribbon spring weakend or damaged?

Replace ribbon spring.

 

 

 

 

Check for proper nails.

Use only recommended nails.

Weak drive.

Check air pressure.

Increase air pressure. (Do not

Slow to cycle.

 

exceed 120 psi (8.3 bars, 8.5 kgf/cm2))

 

———

Use Hitachi pneumatic tool lubricant.

 

 

 

 

Driver blade worn?

Contact Hitachi for replacement.

 

 

 

Piston ring worn or damaged?

 

 

Drives too deep.

Check air pressure.

Reduce air pressure.

 

 

(Adjust 70 – 120 psi)

Skipping nails. Intermittent feed.

Check for proper nails.

Use only recommended nails.

 

 

 

 

Check function of nail feeder per

Clean and lubricate.

 

page 17.

 

 

 

 

 

Ribbon spring weakend or damaged?

Replace ribbon spring.

 

 

 

 

———

Use Hitachi pneumatic tool lubricant.

 

 

 

 

Piston ring cut or heavily worn?

Contact Hitachi for replacement.

Nails jam.

Check for proper nails.

Use only recommended nails.

Driven nail is bent.

 

 

Driver blade worn?

Contact Hitachi for replacement.

 

Drives properly during normal

Check inside diameter of air hose.

Use larger air hose.

operation, but does not drive fully

 

 

at faster nailing speeds.

 

 

 

 

 

— 18 —

Page 18
Image 18
Hitachi Koki USA NR 90AC3 manual Action WHY HOW, Problem Check Method Correction