Hitachi Koki USA NR 90GC Loading Nails, Insert Fuel Cell Into Nailer, Nailer Must not Operate

Models: NR 90GC

1 64
Download 64 pages 33.35 Kb
Page 15
Image 15

(3) INSERT FUEL CELL INTO NAILER.

1Pulling the latch and open the cell cover. Latch

Cell cover

2Insert the fuel cell into nailer.

Fuel cell

3Insert the stem of fuel cell into the hole of adaptor.

Adapter Stem

Fuel cell

Adapter Stem

Fuel cell

4Close the cell cover.

Cell cover

(4)Remove the finger from the trigger and press the push lever against the workpiece with pulling back the feeder knob.

THE NAILER MUST NOT OPERATE.

Depress push lever

Do not pull trigger Feeder knob

English

(5)Separate the push lever from the workpiece.

Next, point the nailer downward, pull the trigger and then wait in that position for 5 seconds or longer.

THE NAILER MUST NOT OPERATE.

Pull trigger

(6)Without touching the trigger, depress the push lever against the workpiece.

Pull the trigger.

THE NAILER MUST OPERATE.

(7)If no abnormal operation is observed, you may load nails in the Nailer.

Drive nails into the workpiece that is the same type to be used in the actual application.

THE NAILER MUST OPERATE PROPERLY.

LOADING NAILS

WARNING

When loading nails into Nailer,

1)do not depress trigger;

2)do not depress push lever; and

3)keep Nailer pointed downward.

2–Action Nail Feeding!

(1) Insert nail strip into the back of the magazine.

Magazine

(2) Slide the nail strip forward in the magazine.

— 15 —

Page 15
Image 15
Hitachi Koki USA NR 90GC manual Loading Nails, Insert Fuel Cell Into Nailer, Nailer Must not Operate, Nailer Must Operate