2-10. Electrical Service Guide
NOTE
All values calculated at 40% duty cycle.
Input Voltage | 230 |
|
|
Input Amperes at Rated Output | 67 |
|
|
Max Recommended Standard Fuse Or Circuit Breaker Rating In Amperes | 100 |
|
|
Min Input Conductor Size In AWG/Kcmil | 8 |
|
|
Max Recommended Input Conductor Length In Feet (Meters) | 166 (51) |
|
|
Min Grounding Conductor Size In AWG/Kcmil | 8 |
|
|
Reference: 1996 National Electrical Code (NEC) | |
|
|
2-11. Connecting Input Power
Tools Needed:
YHave only qualified persons make this installation.
YSpecial installation may be required where gasoline or volatile liquids are present – see NEC Article 511 or CEC Section 20.
Units come equipped with input
GND/PE power cord for installation into line disconnect device. Select type and size overcurrent protection using Section
GND/PE |
|
Connect first. L1 | L2 |