3-2. Example of Front Panel Amperage Control For Stick (SMAW) Welding

Select weld process.

Select polarity.

Select amperage.

 

 

In Example:

 

 

Remote weld amperage = 10–180 amps DC

 

 

NOTE: Remote amperage control is active whenever a

 

 

remote control is connected. If the remote device does not

 

 

include a means of controlling amperage through pin E, the

 

 

Amperage Adjustment control on the front panel remains active.

3-3. Example of Remote Amperage Control For TIG (GTAW) Welding

Select weld process.

Select polarity.

Select max amperage

or

 

In Example:

 

 

For remote amperage control, front panel amperage control setting is the

 

 

maximum amperage available. Full range is 10–180 amps DC, but if front

 

 

 

 

panel amperage control is set at 130 amps, the range of remote

 

 

amperage control is 10 to 130 amps DC. NOTE: Remote amperage

 

 

control is active whenever a remote control is connected. If the

 

 

remote device does not include a means of controlling amperage through

 

 

pin E, the Amperage Adjustment control on the front panel remains active.

Connect remote control (see Section 3-4).

OM-355 Page 15

Page 19
Image 19
Hobart 180 SD manual Example of Remote Amperage Control For TIG Gtaw Welding, Select weld process Select polarity