UNLOADING
1.Open the bowl guard wire cage assembly.
2. Lower bowl support.
3.Remove the agitator from the agitator shaft.
4. Slightly lift the bowl off the pin (right side), pullbowl to the front and remove from the bowl
support (left side).
WIRE CAGE
The bowl guard wire cage can be rotated out of the wayto add ingredients or to access the
bowl and agitator.
Note how the plastic carriers allow the wire cage to ride around the circumference of the pl anetary
drip cup.
xOpen the bowl guard wire cage: rotate it to your left (Fig. 9).
xClose the bowl guard wire cage: rotate it to your right untilit stops, closed position (Fig.
10).
NOTE: The bow l guard wire ca ge must be retu rned to the clo sed pos ition fo r the m ixer to
operate.
Fig. 9 Fig. 10
14