5.SET UP MODE — From the main menu, press [5].
Set Up mode allows you to easily set four parameters for HQC45, HQC90; seven parameters for HQCF45. These parameters could be set according to the type of food, its surface, etc. The user may try different set ups to maximize performance and food quality. On a chiller only model, the grayed freezer temperatures setup menus are omitted. Blasting air differential and holding air differential temperatures are set at the factory.
TARGET TEMPERATURE | The setting for target food temperature in Chill mode is shown. | ||||
|
|
|
|
| |
IN CHILL MODE: 37 |
|
|
|
|
|
|
| Temperature Range | Preset Target Temperature |
| |
|
|
|
|
|
|
|
| Chill Mode | 34° F to 80° F | 37° F |
|
|
|
|
|
|
|
TARGET TEMPERATURE IN FREEZE MODE: 0
BLASTING AIR TEMP. IN CHILL MODE: 10
Enter a value within the range. Press [YES] to continue.
The setting for target food temperature in Freeze mode is shown.
| Temperature Range | Preset Target Temperature |
Freeze Mode | – 22° F to 80° F | 0° F |
|
|
|
Enter a value within the range. Press [YES] to continue.
The setting for blasting air temperature in Chill mode is shown. Air temperature will be maintained between the blasting air temperature and blasting air temperature plus differential.
For Example: Blasting Air Temperature = 10°F. Differential = 4 F°. Temperature will fluctuate between 10°F and 14°F.
| Temperature Range | Preset Blasting Air Temp. |
Chill Mode | 10° F to 45° F | 10° F |
|
|
|
BLASTING AIR TEMP. IN FREEZE MODE: -25
For Example:
Enter a value within the range. Press [YES] to continue.
The setting for blasting air temperature in Freeze mode is shown. Air temperature will be maintained between blasting air temperature and blasting air temperature plus the differential.
Blasting Air Temperature =
| Temperature Range | Preset Blasting Air Temp. |
|
|
|
Freeze Mode | – 32° F to 20° F | – 25° F |
|
|
|
HOLDING COOLER
TEMPERATURE: 35
For Example:
Enter a value within the range. Press [YES] to continue.
The setting for air temperature in Holding Cooler mode is shown. Air temperature will be maintained between the holding cooler temperature and holding cooler temperature plus differential.
Holding Cooler Temperature = 35°F. Differential = 6 F°. Temperature will fluctuate between 35°F and 41°F.
| Temperature Range | Preset Holding Cooler Temp. |
|
|
|
Holding Cooler Mode | 10° F to 45° F | 35° F |
|
|
|
Enter a value within the range. Press [YES] to continue.
– 10 –