2.FREEZE MODE — From the main menu, press [2], when available.
|
| Freeze mode operates exactly like chill mode. Use the menus on | |
FREEZE METHOD:1.AUTO | page 7 except CHILL is replaced by FREEZE. Different target | ||
temperature and air set point may be entered in | |||
2.MANUAL | 3.EXIT | ||
|
Different temperature ranges are available for chill and freeze modes.
After a Freeze cycle is complete, the cabinet goes into Freezer
Hold mode.
3.DEFROST MODE — From the main menu, press [3].
|
|
| To begin a manual defrost cycle, press [YES]. Pressing [NO] will | |
READY | TO | DEFROST | return to the main menu. | |
The top line of the display indicates defrost mode is in progress. | ||||
REMOVE FOOD | [YES] | |||
The coil temperature and the time remaining in the Defrost cycle | ||||
|
|
| ||
UNIT | DEFROSTING | are displayed on the bottom line. Once it has begun, the Defrost | ||
cycle cannot be stopped. The Defrost cycle ends when either the | ||||
COIL=6 | 00:18:42 | |||
coil temperature reaches the Defrost Termination Temperature or | ||||
|
|
| ||
|
|
| when the Defrost Termination Time has elapsed (factory setting is | |
DEFROST | CYCLE DONE | 20 minutes). The Buzzer sounds for two minutes or until [MUTE] | ||
is pressed. | ||||
ACKNOWLEDGE | [YES] | |||
|
Press [YES] and return to the main menu.
NOTE: Different factors influence the ideal frequency of defrost cycles. When you see some frosting on the coil in the cabinet behind the louvers, a Defrost cycle should be performed. If the Defrost cycle is skipped, air circulation in the cabinet will be reduced and chilling or freezing times will increase.
4.HOLD MODE — From the main menu, press [4].
|
|
| If the cabinet is a chiller / freezer, this menu selects which holding | |
1. HOLDING COOLER | air temperature setting is used during a selected Hold mode. After | |||
a chill or freeze cycle, the system automatically selects the | ||||
2. HOLDING FREEZER | ||||
corresponding holding temperature. This menu is omitted if the | ||||
|
|
| ||
|
|
| cabinet is a chiller only model. | |
34 | 35 | 33 | The top row displays the food probe temperatures. The bottom | |
row displays the air temperature, the Hold mode indicator, and the | ||||
AIR=34 HLD | 01:35:45 | |||
time accumulated since the Hold mode began. The compressor | ||||
|
|
|
operates to maintain the air temperature at the selected target temperature in Hold mode. When the temperature is reached, fans stop, and periodically restart to maintain a uniform internal temperature.
NOTE: During Hold mode, an automatic Defrost occurs every six hours. To exit Hold mode, press [STOP] and return to the main menu.
In Hold mode, quick chillers and quick feezers operate like a standard refrigerator or freezer. Probes are ignored and air temperature is maintained at the selected value.
If the message COOLING TOO SLOW displays during Hold mode, the cabinet needs service.
– 9 –