Hobart HQC45, ML-124061 manual MANUAL CHILL - Timed chill cycle. From the main menu, press

Models: ML-124061 HQC45

1 12
Download 12 pages 54.83 Kb
Page 8
Image 8
1.2 MANUAL CHILL — (Timed chill cycle.) From the main menu, press [1] [2].

1.1 AUTOMATIC CHILL — (Controlled by probes, a non-timed chill.) From the main menu, press [1][1].

 

AUTOMATIC

CHILL

OK TO START

[YES/NO]

 

Top

Bottom

 

Probe

Probe

34

45

37

AIR=25 AUTO

01:25:45

CHILL CYCLE STOPPED

REMOVE FOOD [YES]

CHILL CYCLE DONE REMOVE FOOD [YES]

To begin Automatic Chill, press [YES].

The top row displays the food probe temperatures. The left value corresponds to the top probe; the right value corresponds to the bottom probe, etc. The temperature of the air, the AUTO mode indicator, and the chill cycle time are displayed on the bottom row. The compressor operates to cool the air down to the selected blasting air temperature in Chill mode. As each probe reaches the target temperature in Chill mode, an asterisk (*) displays next to its temperature display and the buzzer sounds for two minutes or until the [MUTE] key is pressed. The cycle continues until all probes have reached the target temperature.

If you press the [STOP] key during a chill cycle, the display at left allows you to press [YES] and return to the main menu.

When the Automatic Chill ends, buzzer sounds for two minutes. Pressing [YES] returns to the main menu. If you do not press [YES] within two minutes, the cabinet goes to Cooler Hold mode.

1.2 MANUAL CHILL — (Timed chill cycle.) From the main menu, press [1] [2].

READY TO CHILL FOR

01 HOURS 10 MINUTES?

ENTER NEW CHILL TIME 00 HOURS 00 MINUTES?

READY TO CHILL FOR

00 HOURS 45 MINUTES?

54

58

65

AIR=35

MAN

01:09:59

CHILL CYCLE STOPPED

REMOVE FOOD [YES]

CHILL CYCLE DONE

REMOVE FOOD [YES]

If the chill time setting is OK, press [YES] to begin. If you want to reset the chill time, press [CLEAR].

Enter the chill time as a pair of two-digit numbers (HH:MM) where HH=hours and MM=minutes. Use a leading zero for single digit numbers. Press [YES].

If the chill time setting is OK, press [YES] to begin.

The top row displays the food probe temperatures. The temperature of the air, the MANUAL mode indicator, and the countdown time are displayed on the bottom row. The compressor operates to cool the air down to the selected blasting air temperature in Chill mode. As each probe reaches the target temperature in Chill mode, an asterisk (*) displays next to its temperature display and the buzzer pulses two seconds on, two seconds off for two minutes. The Chill cycle continues until the set time has elapsed.

If you press the [STOP] key during a chill cycle, the display at left allows you to press [YES] and return to the main menu.

When the Manual Chill ends, the buzzer sounds for two minutes. Pressing [YES] returns to the main menu. If you do not press [YES] within two minutes, the cabinet goes to Hold mode.

NOTE: For better performance, precool the cabinet by operating in Hold mode prior to loading product.

A message displays, ERR, when the probe needs to be replaced or when its temperature is out of range.