4-4. Electrical Service Guide

4-4. Electrical Service Guide

S-0092J

.For 230 V models with wall receptacle, 100% duty cycle used to calculate data below. 20% duty cycle used for all other models.

Input Voltage

200

230

380

415

460

 

 

 

 

 

 

Input Amperes at Rated Output

59

52

39

36

33

 

 

 

 

 

 

Standard Fuse or Circuit Breaker Rating

90 Amps

80 Amps

60 Amps

50 Amps

40 Amps

(Max. Recommended)

 

 

 

 

 

 

 

 

 

 

 

Input Conductor Size (Min.)

10 AWG

6 AWG

12 AWG

12 AWG

14 AWG

 

 

 

 

 

 

Input Conductor Length (Max. Recommended)

42 ft (13 m)

135 ft (41 m)

151 ft (46 m)

181 ft (55 m)

85 ft (26 m)

 

 

 

 

 

 

Grounding Conductor Size (Min.)

10 AWG

8 AWG

12 AWG

12 AWG

14 AWG

 

 

 

 

 

 

Reference: 1996 National Electrical Code (NEC).

 

 

 

 

 

4-5. Connecting Input Power

Tools Needed:

GND/PE

 

 

L2

When making connections in the line

 

Install conductors into

 

a deenergized line dis-

disconnect device, connect the Green Or

L1

connect device.

Green/Yellow ground conductor first.

 

 

All Other

 

230 Volt

Models

 

Models Only

L1

YHave only qualified persons make this installation.

YDisconnect and lockout/tag- out input power before con- necting input conductors for wall receptacle or from unit.

YSpecial installation may be required where gasoline or volatile liquids are present – see NEC Article 511 or CEC Section 20.

230 Volt Models:

Units come equipped with input power cord and plug. Wall recep- tacle is customer supplied. To install, select type and size input and grounding conductors using Section 4-4. Conductor rating must comply with national, state, and local electrical codes.

Install and connect grounding con- ductor and input conductors in con- duit or equivalent between wall receptacle and deenergized line disconnect device.

All Other Models:

Units come equipped with input power cord for installation into line disconnect device. Select type and size overcurrent protection using Section 4-4.

GND/PE

L2

230VAC,

14-5. Connecting Input Power

ST-161 454-A

OM-303 Page 14