OM-353 Page 16

3-8. Remote 14 Receptacle

Socket* Socket Information

A24 volts ac.
BContact closure to A completes 24 volts ac contactor control
circuit.
CCommand reference; 0 to +10 volts dc output to remote control.
AJ
BKIDRemote control circuit common.
CLNH
DMG
F
AE0 to +10 volts dc input command signal from remote control.
EF
ST-154 795-C K Chassis common.
*The remaining sockets are not used.

3-9. 115 Volts AC Duplex Receptacle And Shielding Gas Connections

Ref. ST-154 795-C / Ref. ST-157 858
YTurn Off power before
connecting to receptacle.
1 115 V AC Receptacle
Receptacle is protected from over-
load by circuit breaker CB1 (see
Section 5-2).
2 Gas Valve In Fitting
3 Gas Valve Out Fitting
Fittings have 5/8-18 right-hand
threads
4 Cylinder Valve
Open valve slightly so gas flow
blows dirt from valve. Close valve.
5 Regulator/Flow Gauge
6 Flow Adjust
Typical flow rate is 20 cfh (cubic feet
per hour) (9.4 L/min)
7 High Frequency Control (see
Section 4-1)
4
5
6
1 7
3 2