4-5. Connecting Input Power
5
3 4
Or
12
Model | Input Conductor | Fuse/Circuit Breaker |
Size (AWG) | Size In Amperes | |
|
|
|
|
|
|
1.5 kVA 110 Volt | No. 10 | 30 |
2.5 kVA 220 Volt | No. 10 | 30 |
|
|
|
YInput power supply wiring and receptacle must meet National Electrical Code and all other code requirements.
Operate spot welder from a sepa- rately fused or circuit breaker pro- tected circuit, and use correct size input conductors.
1Rating Label
2Cord
3Parallel Plug On 110 Volts AC Models
4Tandem Plug On 220 Volts AC Models
Do not cut ground terminal off plug.
5 Grounded Receptacle
Connect plug to matching grounded receptacle.
Ref.
SECTION 5 − OPERATION
5-1. Controls
1
1 Hand Lever
Use lever to open and close tongs. Close the hand lever during the welding process to compress the material between the tips. To adjust tong pressure, see Section
2 Start Switch
Use switch to turn weld current On and Off. Move switch sideways in either direction to start weld current. Release switch to stop weld cur- rent.
2
Return To Table Of Contents |