SECTION 7 OPERATING AUXILIARY EQUIPMENT

7-1. Standard Receptacles

244 029-A / 281 080-A
!If unit does not have GFCI recep-
tacles, use GFCI-protected exten-
sion cord.
Generator power decreases as weld
current increases.
Set Fine Control R1 at 10 for full gen-
erator power.
1 240 V 50 A AC Receptacle RC1
RC1 supplies 60 Hz single-phase power
at weld/power speed. Maximum output is
11 kVA/kW.
2 120 V 20 A AC Duplex Receptacle
RC2
3 120 V 20 A AC Duplex Receptacle
RC3
RC2 and RC3 supply 60 Hz single-phase
power at weld/power speed. Maximum
output from RC2 or RC3 is 2.4 kVA/kW.
4 240 V 50 A AC Receptacle RC5
RC5 supplies 60 Hz single-phase power
at weld/power speed. Maximum output is
11 kVA/kW.
5 Supplementary Protector CB1
CB1 protects receptacles RC1, RC2,
RC3, and RC5 from overload. If CB1
opens, the receptacles do not work. Place
switch in On position to reset.
6 Supplementary Protector CB2
7 Supplementary Protector CB3
CB2 protects RC2 and CB3 protects RC3
from overload. If a supplementary protec-
tor opens, the receptacle does not work.
Press button to reset. If supplementa-
ry protector continues to open, con-
tact Factory Authorized Service
Agent.
GFCI Receptacle Option
8 120 V 20 A AC GFCI Receptacles
GFCI-2 and GFCI-3
GFCI2 and GFCI3 supply 60 Hz single-
phase power at weld/power speed. Maxi-
mum output from GFCI-2 or GFCI-3 is 2.4
kVA/kW. Circuit protection is the same as
standard receptacles.
If a ground fault is detected, the GFCI Re-
set button pops out and the circuit opens
to disconnect the faulty equipment. Check
for damaged tools, cords, plugs, etc. con-
nected to the receptacle. Press button to
reset receptacle and resume operation.
!Power is still present at the 240 volt
receptacle when only one circuit
breaker trips.
Unplug power cord before attempt-
ing to service accessories or tools.
At least once a month, run engine at
weld/power speed and press Test but-
ton to verify GFCI is working properly.
Combined output of all receptacles limited
to the rating of the generator.
Example: If 20 A is drawn from each 120
V duplex receptacle, only 26 A is available
at the 240V receptacle:
2 x (120 V x 20 A) + (240 V x 26 A) = 11.0
kVA/kW