. A complete Parts List is available at wwwHobartWelders.com

5-3. Grounding Generator To Truck Or Trailer Frame

1 2

GND/PE

3

!Always ground generator frame to vehicle frame to pre- vent electric shock and static electricity hazards.

!Also see AWS Safety & Health Fact Sheet No. 29, Grounding of Portable And Vehicle Mounted Welding Generators.

!Bed liners, shipping skids, and some running gear insu- late the welding generator from the vehicle frame. Al- ways connect a ground wire from the generator equip- ment grounding terminal to bare metal on the vehicle frame as shown.

!If unit does not have GFCI re- ceptacles, use GFCI-pro- tected extension cord.

1Equipment Grounding Terminal (On Front Panel)

2Grounding Cable (Not Supplied)

3Metal Vehicle Frame

Connect cable from equipment ground terminal to metal vehicle frame. Use #8 AWG or larger insu- lated copper wire.

.Electrically bond generator

frame to vehicle frame by met- al-to-metal contact.

rot_grnd1 2010−04 − 800 652-D