Hobart Welding Products OM-498 Operating Auxiliary Equipment, Auxiliary Power Panel 196 921 CSA

Models: OM-498

1 60
Download 60 pages 14.62 Kb
Page 24
Image 24

SECTION 6 – OPERATING AUXILIARY EQUIPMENT

NOTE

The welding generator provides power while welding and with the Current control in any position. However, under these conditions equipment connected to the welding generator may be subject to larger than normal voltage fluctuations. It is recommended that only lamps be powered under these conditions.

6-1. Auxiliary Power Panel 196 921 (CSA)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

1

2

3

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YIf unit does not have GFCI recep- tacles, use GFCI-protected exten- sion cord.

YPower is still present at the 240 volt receptacle when only one circuit breaker trips.

Unplug power cord before attempt- ing to service accessories or tools.

.Auxiliary power decreases as weld current increases.

Set Amperage control at max. for full auxiliary power.

.Place throttle lever in Run position (far right) for auxiliary power.

1 240 V AC Twistlock Receptacle RC1

RC1 supplies 60 Hz single-phase power at weld/power speed. Maximum output is 3.5 kVA/kW.

2120 V 20 A AC Duplex Receptacle RC2

3120 V 20 A AC Duplex Receptacle RC3

RC2 and RC3 supply 60 Hz single-phase power at weld/power speed. Maximum output from RC2 or RC3 is 2.4 kVA/kW.

.Each receptacle of the duplex can pro- vide 15A/1800W.

.Do not parallel the two 120V duplex receptacles.

4 Circuit Breakers CB1 and CB2

196 921

CB1 and CB2 protect RC1 from overload. If CB1 or CB2 opens, RC1 does not work. 120 volts may still be present at RC1.

5 Circuit Breakers CB3 And CB4

CB3 protects RC2 and CB4 protects RC3 from overload. If a circuit breaker opens, the receptacle does not work.

.Press button to reset circuit breaker. If breaker continues to open, contact Factory Authorized Service Agent.

Combined output of all receptacles limited to 3.5 kVA/kW rating of the generator (See Section 10 – Auxiliary Power Guidelines).

EXAMPLE: If 5 A is drawn from each 120 receptacle, only 9 A is available from the 240 V receptacle.

2 x (120 V x 5 A) + (240 V x 9 A) = 3.5 kVA/ KW.

OM-498 Page 20

Page 24
Image 24
Hobart Welding Products OM-498 manual Operating Auxiliary Equipment, Auxiliary Power Panel 196 921 CSA