SECTION 3 − SPECIFICATIONS

3-1. Specifications

Rated Welding

Amperage

Maximum Open-

Amperes Input at

 

 

Weight

 

Overall

Rated Load Output

 

 

 

Circuit Voltage

KVA

KW

 

Output

Range

115 V, 60 Hz, Single-

W/ Gun

 

Dimensions

DC

 

 

 

 

 

Phase

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Length: 16-7/8 in

90 A @ 19 Volts DC,

 

 

20

2.90

2.50

50 lb

 

(429 mm)

20% Duty Cycle

 

 

 

Width: 9-7/8 in

 

30 − 125

29

 

 

 

(22.7 kg)

 

63 A @ 21 Volts DC,

 

 

 

 

(251 mm)

 

 

15*

2.20*

1.77*

 

 

 

 

 

 

 

20% Duty Cycle*

 

 

 

 

 

 

 

Height: 12-1/8 in

 

 

 

 

 

 

 

 

(308 mm)

 

 

 

 

 

 

 

 

 

 

Flux Cored

Solid/

 

Wire Feed Speed Range

 

Wire Type

 

Stainless**

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

And Dia

 

 

 

 

.030 − .035 in

.024 − .030 in

0 − 500 IPM (0 − 13 m/min) At No Load

 

 

(0.8 − 0.9 mm)

(0.6 − 0.8 mm)

0 − 415 IPM (0 − 11 m/min) Feeding Wire

 

 

 

 

 

 

 

 

 

 

* CSA Rating

** When shielding gas is required, MIG conversion kit 195 158 must be installed.

3-2. Duty Cycle And Overheating

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Duty Cycle is percentage of 10 min-

 

 

 

 

 

 

 

 

 

 

utes that unit can weld at rated load

 

 

 

 

 

 

 

 

 

 

without overheating.

 

 

 

 

 

 

 

 

 

 

If unit overheats, thermostat(s)

 

 

 

 

 

 

 

 

 

 

opens, output stops, and cooling

 

 

 

 

 

 

 

 

 

 

fan runs. Wait fifteen minutes for

Amperes

 

 

 

 

 

 

 

 

 

unit to cool. Reduce amperage or

200

 

 

 

 

 

 

 

 

duty cycle before welding.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

135

 

 

 

 

 

 

 

 

Y Exceeding duty cycle can

 

 

 

 

 

 

 

 

 

damage unit or gun and void

Output

100

 

 

 

 

 

 

 

 

warranty.

 

 

 

 

 

 

 

 

 

80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60

 

 

 

 

 

 

 

 

 

 

40

 

 

 

 

 

 

 

 

 

 

20

 

 

 

 

 

 

 

 

 

 

10

2

4

6

8

10

 

40

60

80 100

 

1

20

 

 

 

 

Duty Cycle %

 

 

 

 

 

 

20% duty cycle at 90 amps

 

 

 

 

 

2 Minutes Welding

 

 

 

8 Minutes Resting

 

 

Overheating

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

A or V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

 

 

OR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minutes

 

 

Reduce Duty Cycle

 

 

 

 

 

 

 

 

duty1 4/95 − 210 517

 

 

 

 

 

 

 

 

 

 

OM-947 Page 9

Page 13
Image 13
Hobart Welding Products OM-947 212 149D manual Specifications, Duty Cycle And Overheating