¾Press 4 (LVL) to set the desired lighting level of the selected unit
¾5 (RMP) does not affect CentraLite units.
¾Press 9 (TIM) to time the selected unit (On or Off). Timed commands may be from
¾Press # (STA) to see the status (On or Off) of a CentraLite device.
Controlling RadioRA Units
Entry Lights
0=OFF 1=ON 2=DIM 3=BRT ↓
Entry Lights
4=LVL 5=RMP 9=TIM #=STA↑
¾Press 0 (OFF) to turn the selected unit off
¾Press 1 (ON) to turn the selected unit on.
¾2 (DIM) does not affect RadioRA units.
¾3 (BRT) does not affect RadioRA units.
¾Press 4 (LVL) to set the desired lighting level of the selected unit
¾5 (RMP) does not affect RadioRA units.
¾Press 9 (TIM) to time the selected unit (On or Off). Timed commands may be from
¾Press # (STA) to see the status (On or Off) of a RadioRA device.
Note: When a RadioRA device transmits a signal (i.e. Switch or Dimmer is turned on or off locally, Mater Control button is pressed, or Phantom Button is executed), OmniPro II will automatically update the status of each affected device.
Controlling ALC or X-10 Units
Entry Lights
0=OFF 1=ON 2=DIM 3=BRT ↓
Entry Lights
4=LVL 5=RMP 9=TIM #=STA↑
¾Press 0 (OFF) to turn the selected unit off.
¾Press 1 (ON) to turn the selected unit on.
¾Press 2 (DIM) to dim the selected unit
¾Press 3 (BRT) to brighten the selected unit
¾Press 4 (LVL) to set the desired lighting level of the selected unit
¾Press 5 (RMP) to ramp the lighting level of an ALC Dimmer Switch to a new level at a selectable ramp rate.
• 5 (RMP) does not affect
¾Press 9 (TIM) to time the selected unit (On or Off). Timed commands may be from
¾Press # (STA) to view the current status of the unit.
Page 23