Corresponding Switch Table
Switch | OmniPro II | UPB | UPB | RadioRA Master Control | ALC |
1 | 2 | On Button | 1 or E | 1 | 1 |
2 | 3 | Off Button | 2 or F | 2 | 2 |
3 | 4 | A | 3 or G | 3 | 3 |
4 | 5 | B | 4 or H | 4 | 4 |
5 | 6 | C | 5 or I | 5 |
|
6 | 7 | D | 6 or J | 6 |
|
7 | 8 |
| 7 or K | 7 |
|
8 | 9 |
| 8 or L | 8 |
|
9 | 10 |
|
| 9 |
|
10 | 11 |
|
| 10 |
|
Security Mode Event Buttons
Pressing the 2 (SEC) key allows you to select the event button that will be activated when a security mode changes:
0=OFF 1=DAY 2=NIGHT 3=AWAY 4=VACATION
After the security mode is selected, an additional menu appears which allows you to further specify the event button. For example, you would like to activate an event button when you arm the system into the 3 (AWAY) mode:
WHEN AWAY:
1=DELAY 2=CODE 3=AREA
Any of these may be selected alone or in combination. As each item is specified, the menu is redisplayed with the updated event button description. Press the ' # ' key when done.
-Selecting 1 (DLY) allows the user to specify whether the event button is activated at the start or end of the exit delay:
WHEN ACTIVATED?
1=START EXIT 2=END EXIT
When you specify that the event button is activated at the start of the delay by pressing the 1 (START EXIT) key, the mode is prefixed by
WHEN | AWAY: | (END OF DELAY) |
WHEN | (START OF DELAY) |
When the system is armed in the Day (instant) or Night (delay) mode, event buttons for the Day and Night modes are executed, respectively.
-Selecting 2 (CODE) allows you to specify that the event button is activated only when a particular code is used. You will be prompted to enter the code:
ENTER USER CODE: | 0=ALL ↓ |
You should enter the user code by entering the code number followed by the ' # ' key or by using the arrow keys to scroll through a list of code names.
WHEN C1 AWAY:
1=DELAY 2=CODE 3=AREA
-Selecting 3 (AREA) allows you to specify that the event button is activated only when the specified area is armed or disarmed. You will be prompted to enter the area:
Page 62