Homelite HG5000 manuel dutilisation Features

Models: HG5000

1 60
Download 60 pages 51.88 Kb
Page 14
Image 14
FEATURES

FEATURES

PRODUCT SPECIFICATIONS

Engine

Engine Type

389cc OHV

Cooling System

Forced Air

Starting System

Recoil

Ignition System

TMI

Spark Plug

Champion F7TC

Engine Lubricant Volume

1.16 qt.

Fuel Volume

6.6 gal.

Generator

 

Rated Voltage

120V/240V

Rated Amps

41.6/20.8A

Running Output

5,000 W

Starting Output

6,250 W

Rated Frequency

60 Hz

Dimensions

 

Length

31 in.

Width

26 in.

Height

24 in.

Weight

167.6 lbs.

KNOW YOUR GENERATOR

See Figure 1.

The safe use of this product requires an understanding of the information on the product and in this operator’s manual as well as a knowledge of the project you are attempting. Before use of this product, familiarize yourself with all operating­ features and safety rules.

AC circuit breakerS

The circuit breakers are provided to protect the generator against electrical overload. The circuit breaker may be reset by lifting the circuit breaker reset lever.

air filter

The air filter helps to limit the amount of dirt and dust drawn into the unit during operation.

choke lever

The choke lever is used when starting the engine.

fuel tank

The fuel tank has a capacity of 6.6 gallons.

fuel valve

The flow of fuel through the generator is controlled by the position of the fuel valve.

ground terminal

The ground terminal is used to assist in properly ground- ing the generator to help protect against electrical shock. Consult with a local electrician for grounding requirements in your area.

MULTIFUNCTIONAL DIGITAL DISPLAY

The multifunctional digital display indicates voltage, frequen- cy, and hours of operation for the current usage period.

oil cap

Remove the oil fill cap to check and add lubricant to the generator when necessary.

oil drainage bolt

When changing the engine lubricant, the oil drainage bolt is loosened to allow old engine lubricant to be drained.

receptacleS

Your generator has the following single phase, 60 Hz outlets: two 120 Volt AC, 20 Amp duplex receptacles, and one 120/240 Volt AC, 30 Amp twist-lock receptacle. These can be used for operating appropriate appliances, electrical lighting, tools, and motor loads.

recoil starter grip

The recoil starter grip is used (along with the engine switch) to start the generator’s engine.

Page 10 — English

Page 14
Image 14
Homelite HG5000 manuel dutilisation Features