operation

APPLICATIONS

This generator is designed to supply electrical power for operating compatible electrical lighting, appliances, tools, and motor loads.

BEFORE OPERATING the UNIT

Only use OUTSIDE and far away from windows, doors, and vents.

NEVER use inside a home or garage, EVEN IF doors and windows are open.

Always position the generator on a flat firm surface.

CAUTION:

Attempting to start the engine before it has been properly filled with lubricant will result in equipment failure.

checking/adding lubricant

See Figure 7.

Engine lubricant has a major influence on engine perfor- mance and service life. For general, all-temperature use, SAE 10W-30 is recommended. Always use a 4-stroke motor lubricant that meets or exceeds the requirements for API service classification SJ.

NOTE:Non-detergent or 2-stroke engine lubricants will damage the engine and should not be used.

Unscrew the oil cap/dipstick and remove.

Wipe dipstick clean and re-seat in hole; do not re- thread.

Remove dipstick again and check lubricant level. Lubri- cant level should fall between the hatched areas on the dipstick.

If level is low, add engine lubricant until the fluid level rises to the upper portion of the dipstick.

Replace and secure the oil cap/dipstick.

checking/adding fuel

See Figure 8.

Remove the fuel cap.

Fill the fuel tank to 1 in. below the top of the fuel neck.

Replace and secure the fuel cap.

NOTE:  Always use unleaded gasoline with a pump octane rating of 86 or higher. Never use old, stale, or contaminated gasoline, and do not use an oil/gas mixture. Do not allow dirt or water into the fuel tank.

using fuel stabilizer

Fuel gets old, oxidizes, and breaks down over time. Adding a fuel stabilizer (not included) extends the usable life of fuel and helps prevent deposits from forming that can clog the fuel system. Follow fuel stabilizer manufacturer’s directions for correct ratio of stabilizer to fuel.

Add stabilizer to fuel tank, then fill with gasoline following previous instructions.

NOTE:  Fuel stabilizer and gasoline can be mixed prior to filling the tank by using a gas can or other approved fuel container and shaking gently to combine.

Replace and secure the fuel tank cap.

Start and run the engine for at least 5 minutes to allow stabilizer to treat the entire fuel system.

OXYGENATED FUELS

DO NOT USE E85 FUEL. IT WILL VOID YOUR WARRANTY.

NOTE: Fuel system damage or performance problems re- sulting from the use of an oxygenated fuel containing more than the percentages of oxygenates stated previously are not covered under warranty.

Ethanol. Gasoline containing up to 10% ethanol by volume (commonly referred to as E10) or 15% ethanol by volume (commonly referred to as E15) are acceptable. E85 is not.

CAUTION:

On a level surface with the engine off, check the lubricant level before each use of the generator.

Starting the engine

See Figures 9 - 11.

NOTE:  If location of generator is not level, the unit may not start or may shut down during operation.

Unplug all loads from the generator.

Turn the fuel valve to the ON position.

Put the engine switch in the ON position.

Pull choke.

Grasp the recoil starter and pull slowly until resistance is felt. Give the recoil starter a short, brisk pull to start the engine.

NOTE: Do not allow the recoil starter to snap back after starting; return it gently to its original place.

Let engine run for several seconds, then push choke in.

Stopping the engine

See Figures 9 - 11.

To stop the engine under normal operating conditions:

Remove any load from the generator.

Turn the fuel valve to the OFF position.

Put the engine switch in the OFF ( O ) position.

To stop the engine in an emergency situation:

Put the engine switch in the OFF ( O ) position.

MULTIFUNCTIONAL DIGITAL DISPLAY

The multifunctional digital display indicates voltage, frequen- cy, and hours of operation for the current usage period.