15
CONTROLS & FEATURES
Voltage Selector Switch
Switch Position
AC Circuit Breaker
120V/240V:
120V ONLY:
ON
OFF
VOLTAGE SELECTOR SWITCH
120V/240V
120VONLY
AC CIRCUIT BREAKER
The voltage selector switch switches generator output to produce
‘‘120V ONLY’’ or ‘‘120V/240V.’’ If a 240V appliance is connected to the
4-prong receptacle, the switch must be in the ‘‘120V/240V’’ position. If
only a 120V appliance is being connected to any of the 120V 3-prong
receptacles, select the ‘‘120V ONLY’’ position.
Select the voltage before starting the engine.
The AC circuit breaker may be used to switch the generator power ON
or OFF.
The AC circuit breaker will automatically switch OFF if there is a short
circuit or a significant overload at the receptacles.
The 120V and 120V/240V receptacles can be used
simultaneously.
ONLY the 120V receptacles can be used. Do not use the
120V/240V receptacle in this position. The most power will be
available at the 30A 120V locking plug receptacle.
10/08/27 13:26:13 31Z30600_016