26
OPERATION
AC OPERATION
PLUG
VOLTAGE SELECTOR SWITCH
120V/240V
120VONLY
AC CIRCUIT BREAKER
ON
: Except EG4000CL
AC CIRCUIT PROTECTORS
If an appliance begins to operate abnormally, becomes sluggish, or
stops suddenly, turn it off immediately. Disconnect the appliance, and
determine whether the problem is in the appliance or the rated load
capacity of the generator has been exceeded.
Substantial overloading may damage the generator. Marginaloverloading may shorten the service life of the generator.
With the voltage selector switch
in the ‘‘120V/240V’’ position,
you can use the 120V and 120V/
240V receptacles
simultaneously. If you are NOT
using the 120V/240V receptacle,
then select the ‘‘120V ONLY’’
position.
Turn the voltage selector switch
to either position.
Most motorized appliances
require more than their rated
wattage for startup.
Start the engine (see page ).
Switch ON the AC circuit breaker.
Plug in the appliance.
Turn on the appliance.
Do not exceed the current limit specified for any one receptacle. If an
overloaded circuit causes the AC circuit breaker or AC circuit protector
to switch OFF, reduce the electrical load on the circuit, wait a few
minutes and then reset the AC circuit breaker or AC circuit protector.
1.
2.
3.
4.
22
5.
10/08/27 13:27:54 31Z30600_027