49
STORAGE
STORAGE TIME RECOMMENDED SERVICE PROCEDURE TO
PREVENT HARD STARTING
Service according to the table below:
Less than 1 month
1 to 2 months
2 months to 1 year
1 year or more
Use gasoline stabilizers that are formulated to extend storage life.
Follow the manufacturer’s instructions for use.
Contact your authorized Honda generator dealer for stabilizer
recommendations.
No preparation required
Fill with fresh gasoline and add gasoline
stabilizer *.
Fill with fresh gasoline and add gasoline
stabilizer *.
Drain the carburetor float bowl (page 50 ).
Drain the fuel sediment cup (page 47 ).
Fill with fresh gasoline and add gasoline
stabilizer *.
Drain the carburetor float bowl (page 50 ).
Drain the fuel sediment cup (page 47 ).
Remove the spark plug. Put a teaspoon of
engine oil into the cylinder. Turn the engine
slowly with the pull rope to distribute the oil.
Reinstall the spark plug.
Change the engine oil (page 39 ).
After removal from storage, drain the stored
gasoline into a suitable container, and fill with
fresh gasoline before starting.
*