4.5 Installer Parameters Table

4.5.1 Category 1 - Room Thermostat Settings

Parameter

Parameter Factory Default Setting No.

Optional Setting

Category 1 Parameters – Room Thermostat Settings

 

 

Display

Description

Display

Description

 

 

 

 

 

 

AM-PM / 24hr

1:CL

24

24 hr clock display

12

12 hr – AM/PM clock display format

Display

 

 

format

 

 

 

 

 

 

 

 

Reset Time/ Temp

2:rP

1

Time / Temp profile set

0

Time / Temperature are as programmed

Program

 

 

to factory default

 

 

 

 

 

Changes to 0 when

 

To restore the factory profile set to 1

 

 

 

one of the time/temp

 

 

 

 

 

profiles are changed

 

 

 

 

 

 

 

 

Auto Summer/

3:tC

1

Auto Summer/Winter

0

Auto Summer/Winter Time Change

Winter Time

 

 

Time Change Enabled

 

Disabled

Change

 

 

 

 

 

 

 

 

 

 

 

LCD Backlighting

5:bL

1

Backlighting Enable

0

Backlighting Disabled

 

 

 

 

 

 

Upper Temp Limit

6:uL

35

35°C Upper Temp.

21 to

21°C to 34°C adjustment in 1°C steps

 

 

 

Limit

34

 

 

 

 

 

 

 

Lower Temp Limit

7:LL

5

5°C Lower Temp. Limit

5 to 21

6°C to 21°C adjustment in 1°C steps

 

 

 

 

 

 

Optimisation

8:OP

0

Optimisation Disabled

1

Optimisation Enabled

 

 

 

 

 

 

Temperature Offset

12:tO

0

No temperature offset

-3 to

-3°C to +3°C adjustment in 0.1°C steps

 

 

 

 

+3

 

 

 

 

 

 

 

Proportional Band

13:Pb

1.5

Proportional band of

1.6 to

1.6°C to 3.0°C adjustment in 0.1°C steps

Width

 

 

1.5 degrees

3.0

 

 

 

 

 

 

 

Reset Parameters

19:FS

1

All settings at factory

0

Settings are as modified above

to Factory Defaults

 

 

defaults

 

 

 

 

 

Changes to 0 when

 

To restore the factory profile set to 1

 

 

 

one of the parameter

 

 

 

 

 

is changed

 

 

 

 

 

 

 

 