6) Trouble Shooting

6.1 Trouble Shooting Guide

Symptom (Fault

Possible Cause

Remedy

 

Message)

 

 

 

 

 

 

 

The room thermostat

This is normal operation. The receiver box

Using the

button change the

displays the symbol but

cycles the relay on and off for times proportional

temperature setpoint by a few degrees.

the receiver box relay does

to the demand signal (0-100%) from the room

The receiver box should switch the relay

not switch on.

thermostat. The symbol only indicates that the

on after a few seconds delay.

 

demand value is greater than 0%.

 

 

 

 

 

The receiver box does not

The room thermostat and receiver box are not

Reset the receiver box by pressing and

react to setpoint changes

bound.

holding the push button for 15 seconds.

on the room thermostat.

 

Then follow the binding / rebinding

 

 

procedure as described in section 5)

 

 

Additional Installation Information.

 

 

 

After the binding procedure

Incorrect or incomplete binding procedure.

Repeat the binding procedure.

the red LED is on and the

Incorrect position of the room thermostat during

Repeat the binding procedure keeping

green one is flashing once

binding.

approx. 1 m distance between the receiver

every 3 sec on the receiver

 

box and the room thermostat.

box.

 

 

 

 

 

 

 

 

The red LED on the

The receiver box receives no RF messages from

 

 

receiver box is illuminated

the room thermostat:

 

 

(Communication loss)

RF signal is blocked due to wrong location of the

Re-locate the room thermostat following

 

 

room thermostat.

instructions in section 2) Installing the

 

 

CM900 Wireless System.

 

Room thermostat batteries are exhausted.

Replace batteries in the room thermostat.

 

 

 

 

6.2 Diagnostic Mode

The CM927/921 room thermostat has a user accessible mode that provides information useful to a remote service person and a means of checking whether the boiler is working. To access this move the slider switch to the OFF position then press and hold the button for 5 seconds. The room thermostat will enter

the user settings mode. Next press and hold the and buttons together. The room thermostat will hold the relay on for 5 minutes and the following information can be viewed on the display by pressing the

or buttons. : model ID, date code (WW/YY) & checksum.

Hereby, Honeywell declares that this CM927/CM921 room thermostat and HC60NG receiver box are in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC, 73/23EC and 89/336EC.

“Manufactured for and on behalf of the Environment and Combustion Controls Division of Honeywell Technologies Sàrl, Ecublens, Route du Bois 37, Switzerland by its Authorised Representative Honeywell International Inc.”

Honeywell Control Systems Ltd.

Arlington Business Park, Bracknell, Berkshire RG12 1EB

Technical Help Desk: 08457 678999 www.honeywelluk.com

42011076-003 R2

© 2006 Honeywell International Inc.

Page 13
Image 13
Honeywell 42011076-003 manual Trouble Shooting Guide, Diagnostic Mode