Installation

10/07 Installation and Maintenance Manual 7

3.5 Torque Recommendations

For inserting a cell in metal fittings or bushings - 40 ft-lb maximum. For inserting a cell in plastic fittings

or bushings - 10 ft-lb maximum. Always use pipe sealant (preferably Teflon tape).

3.6 Dimension Drawings

CELL
IN
11/2"
(38mm)
83/4"
(222mm)
14 1/2" max
(368mm)
3/4" Fit ting
Allow 41/ 8"(105mm) for re
CELL
IN
11/2"
(38mm)
83/4"
(222mm)
14 1/2" max
(368mm)
3/4" Fit ting
Allow 41/ 8"(105mm) for re mo val of ce llmoval of cell
3/4" NPT
(Male)
Flow In
Flow Chamb er
11/2"
(38mm)
Octa gon
3/4" NPT (F emale)
Flow Out
11/2"
(38mm)
11/8"
(38mm)
Hexagon
3/4" NPT
(Male)
Flow In
Flow Chamb er
11/2"
(38mm)
Octa gon
3/4" NPT (F emale)
Flow Out
11/2"
(38mm)
11/8"
(38mm)
Hexagon
2" min.
(51mm)
CELL IN
a/n23 342
Notes:
1. Mount cell and flow chamber horizontally as shown above with flow exit up to eliminate
possible air gap around cell body.
2. If cell and flow chamber must be mounted vertically, attach a short length of tubing to flow
exit as shown below and form a trap to ensure filling of flow chamber, especially at low flow.

Figure 3-1 Dimension Drawing for 055919 Flow Chamber