Configuring via the Web Server
Configuring the System
Steps: Use the descriptions in the following table to configure each output device:
Table | Configuration > Other I/O & Groups > Outputs Tab > Fields | |
|
|
|
Setting |
| Description |
|
|
|
Name |
| Enter a unique name to identify the device. |
|
|
|
Pulse Time |
| Specifies the duration for which the device will assume |
|
| abnormal status. For example, it specifies how long a horn will |
|
| sound or a door strike will remain released. The maximum |
|
| number of hours is 1. When the hour field is blank, the |
|
| maximum number of minutes is 59. When 1 is entered in the |
|
| hour field, the maximum number of minutes is 45. The sum of |
|
| all three units comprises the pulse time. Note that you can |
|
| express seconds in tenths of a second. |
|
|
|
Time Zones |
| Defines the period of time during which inputs, outputs, groups, |
|
| readers, access levels, and cards will either be energized or |
|
| |
|
|
|
Latching |
| When selected, this toggles a relay with either a valid card, |
|
| interlock, or manual pulse. |
|
|
|
Interlock |
| Enables you to disable the interlock, or programmed interaction |
|
| between two points. |
|
|
|