Replacing electronic air cleaner components

Replacing electronic air cleaner components

STEP 1

Inspect the cell(s) for broken ionizer wires and

 

bent collector plates. Repair as necessary or

 

take to a Honeywell Authorized Air Cleaner

 

Repair Station.

STEP 2

Slide the prefilter(s) into the upstream prefilter

 

guides.

STEP 3

Slide the air cleaner cell(s) in so the air flow

 

arrow points downstream and the handle(s)

 

face outward.

STEP 4

Firmly close the access door.

STEP 5

Turn on the air cleaner. If the cell(s) and

 

prefilter(s) are wet, the neon light may not come

 

on and you may hear arcing. If the arcing is

 

annoying, simply turn the air cleaner off for 2-3

 

hours or until the cell(s) are dry.

 

If your air cleaner has an Air Cleaner Monitor,

 

the FAULT indicator may activate if you install

 

wet cell(s) and prefilter(s). Again, if the neon

 

light or the FAULT indicator annoys you, simply

 

turn off the air cleaner for 2-3 hours or until the

 

cell(s) and prefilter(s) are dry.