Replacing electronic air cleaner components
STEP 1 | Inspect the cell(s) for broken ionizer wires and |
| bent collector plates. Repair as necessary or |
| take to a Honeywell Authorized Air Cleaner |
| Repair Station. |
STEP 2 | Slide the prefilter(s) into the upstream prefilter |
| guides. |
STEP 3 | Slide the air cleaner cell(s) in so the air flow |
| arrow points downstream and the handle(s) |
| face outward. |
STEP 4 | Firmly close the access door. |
STEP 5 | Turn on the air cleaner. If the cell(s) and |
| prefilter(s) are wet, the neon light may not come |
| on and you may hear arcing. If the arcing is |
| annoying, simply turn the air cleaner off for |
| hours or until the cell(s) are dry. |
| If your air cleaner has an Air Cleaner Monitor, |
| the FAULT indicator may activate if you install |
| wet cell(s) and prefilter(s). Again, if the neon |
| light or the FAULT indicator annoys you, simply |
| turn off the air cleaner for |
| cell(s) and prefilter(s) are dry. |