IPGSM-DPC Commercial Fire Communicator – Installation and Setup Guide

Installation

ULC Compliance

To meet Canadian ULC compliance, ensure the following:

IPGSM-DPC must be installed in accordance with Canadian Electrical Code, Part 1.

IPGSM-DPC must be mounted in the same room and within 20 feet of the fire panel. The wiring must be routed through conduit.

IPGSM-DPC, and all equipment used for the IP connection (such as the router, hub, modem, etc.) shall be listed, must be powered from an un-switched branch circuit, and be provided with appropriate standby power.

IPGSM-DPC must use a 7AH battery (not supplied) to provide 24-hour backup capability.

STEP 1 – Setup the Customer Account

The communicator requires a subscriber account (customer account) to be setup with AlarmNet Direct. This is accomplished by registering the communicator's iGSM communications module with AlarmNet. Registering, enables the fire panel to send reports.

To setup the customer account you will need to contact the central monitoring station to get account information, and have access to the AlarmNet Direct website. To access the AlarmNet Direct website visit – https://services.alarmnet.com/AlarmNetDirect

If you do not wish to use the AlarmNet Direct website, you may call AlarmNet to setup the account, just phone 800-222-6525, then select option 1.

(Monday–Friday 8:00 am to 9:00 pm, Saturday 9:00 am to 5:30 pm EST)

Have the following information ready:

Primary City ID (two digits), obtained from your monitoring station.

Primary Central Station ID (two digits), obtained from your monitoring station.

Primary Subscriber ID (four digits), obtained from your monitoring station.

Communication Module's MAC ID, and MAC CRC number located on outside of box, and inside of the module.

Note: The SIM supplied for the IPGSM-DPC is already activated. Therefore no SIM activation is necessary.

STEP 2 – Register the Communications Module with AlarmNet

Registering the module activates the account with AlarmNet and enables the fire system's control panel to send reports. There are three methods that can be used to register the communications module.

Register the module by logging into AlarmNet Direct and choosing “Show Programmed Devices GSM/I”. Search for the account using the Account Information or MAC ID. Under the “Actions” column, use the pulldown menu and choose Register. OR

After the IPGSM-DPC is installed and programmed, you can register the module by clicking the Tamper Switch 3 times. OR

After the IPGSM-DPC is installed and programmed, you can register the module using the 7720P Programming tool. Simply: Press [Shift ] then press []. Please wait for "Registration SUCCESS" message.

3

Page 5
Image 5
Honeywell IPGSM-DPC manual Installation, ULC Compliance, Setup the Customer Account

IPGSM-DPC specifications

The Honeywell IPGSM-DPC is an advanced communication device designed for alarm systems, providing a reliable and robust connection to monitoring services. This dual-path communicator integrates both internet and cellular technologies, ensuring that security alarm signals are transmitted without interruption. Its ability to utilize both pathways enhances the reliability of the alarm signals, especially in situations where one mode of communication might fail.

One of the standout features of the IPGSM-DPC is its compatibility with Honeywell's Total Connect service, which allows users to remotely monitor and manage their security systems via a smartphone, tablet, or computer. This feature provides real-time alerts and updates, giving users peace of mind and control over their security environment. With Total Connect, users can also receive notifications for certain events like alarm triggers or system status changes.

The IPGSM-DPC is built with the latest in wireless communication technology. It operates on the LTE (Long-Term Evolution) network, which ensures fast data transmission speeds and a wider coverage area. Additionally, the device supports multiple communication formats, making it flexible and adaptable to various alarm panel configurations. This versatility allows for easy integration into existing security systems without the need for extensive rewiring or hardware replacements.

Moreover, the Honeywell IPGSM-DPC features a built-in backup battery, ensuring continued operation even in the event of a power outage. This added layer of security is crucial for maintaining protection during emergencies. The device is designed with user-friendly installation in mind, allowing both professionals and DIY users to set it up quickly and efficiently.

Another notable characteristic is its robust encryption methods, which protect data during transmission. This ensures that sensitive information related to security alarms remains secure from potential cyber threats. The IPGSM-DPC is also equipped with diagnostic features, allowing users to monitor the health and performance of their communication paths, helping to preemptively address any connectivity issues.

In summary, the Honeywell IPGSM-DPC is a state-of-the-art dual-path communicator that enhances the reliability and security of alarm systems. With its integration capabilities, robust cellular technology, user-friendly installation process, and advanced security features, it stands out as an essential component for modern security solutions. Whether used in residential or commercial applications, it offers peace of mind and advanced control over alarm systems.