Honeywell
MK VI MK VIII EGPWS Installation Design Guide
Proprietary notice on title page applies
CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-150 REV: SHEET 186
TABLE 5.3.2-255: AIR DATA INPUT SELECT #255
CHANNEL
429/422RX_1
CONNECT TO: IOC #1
Format: ARINC 429 (High Speed)
Fault Designation: IOC BUS 1
Bus Type: Basic
A = J2-37
B = J2-36
Data
Uncorrected Baro. Alt
Corrected Baro. Alt
Computed Airspeed
True Airspeed
Barometric Rate
Static Air Temperature
Reference
6.2.1
6.2.38
6.2.39
6.2.40
6.2.3
6.2.2
Label
203
204
206
210
212
213
Sig. Bits
17
17
14
15
11
11
Range
±131,072 FT
±131,072 FT
±1024 KTS
±2048 KTS
±32678 FPM
±512 Degrees
Signal Type
Basic
Basic
Basic
Basic
Basic
Basic
Resolution
1.0
1.0
0.0625
0.0625
16.0
0.25
Rate (ms)
31.3-62.5
31.3-62.5
62.5-125
62.5-125
31.3-62.5
250-500
CHANNEL
429RX_3
CONNECT TO: IOC #2
Format: ARINC 429 (High Speed)
Fault Designation: IOC BUS 2
Bus Type: Basic
A = J2-41
B = J2-40
Data
Uncorrected Baro. Alt
Corrected Baro. Alt
Computed Airspeed
True Airspeed
Barometric Rate
Static Air Temperature
Reference
6.2.1
6.2.38
6.2.39
6.2.40
6.2.3
6.2.2
Label
203
204
206
210
212
213
Sig. Bits
17
17
14
15
11
11
Range
±131,072 FT
±131,072 FT
±1024 KTS
±2048 KTS
±32678 FPM
±512 Degrees
Signal Type
Basic
Basic
Basic
Basic
Basic
Basic
Resolution
1.0
1.0
0.0625
0.0625
16.0
0.25
Rate (ms)
31.3-62.5
31.3-62.5
62.5-125
62.5-125
31.3-62.5
250-500