Honeywell
MK VI MK VIII EGPWS Installation Design Guide
Proprietary notice on title page applies
CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-150 REV: SHEET 274
Signal Dynamic Range: –100 to +3200 Feet
Signal Reasonable Range: –30 to +2800 Feet
Signal Open Wire Threshold –50 Feet
Reference Dynamic Range: None
Reference Reasonable Range: None
Scale: RALT (ft) = 250 ft/VDC * Voltsin
Input Signal Connection: (+) = J1-64, (–) = J1-45
Input Reference Connection: None
AIC Name: D1 (DC1)
External Validity Flag Connection: J1-29
AIC LSB: 0.25 Feet
AIC Status Mask: 0000200C
External Validity Type: Discrete Validity
6.1.12 Pitch Synchro Attitude, 3 Wire Synchro (11.8 VAC )
Data Item Value
Signal Name: Pitch Attitude, 3 Wire Synchro
AIC Algorithm: 3 Wire Synchro (11.8 VAC)
Signal Dynamic Range: ±90° Synchro Angle (15.5 VAC max)
Signal Reasonable Range: ±80° Synchro Angle
Signal Open Wire Threshold None
Reference Dynamic Range: None
Reference Reasonable Range: None
Scale: Pitch Angle (deg) = 1 deg/deg
Input Signal Connection: (X) = J1-5, (Y) = J1-7, (Z) = J1-6
Input Reference Connection: None
AIC Name: S3 (Synchro #3)
External Validity Flag Connection: J1-68 (Common Validity with Roll Attitude 6.1.15)
AIC FIFO LSB: 0.00549316°
AIC Status Mask: 0000010F
External Validity Type: Discrete Validity
6.1.13 Uncorrected Barometric Altitude (CIC 02702)
Data Item Value
Signal Name: Uncorrected Baro Altitude, DC Voltage
AIC Algorithm: DC Absolute
Signal Dynamic Range: –3713 to +62,017 Feet
Signal Reasonable Range: –1000 to +40,000 Feet
Signal Open Wire Threshold –3000 Feet
Reference Dynamic Range: None
Reference Reasonable Range: None
Scale: Altitude (Feet) = 4100 Feet/VDC * Volts – 1000 Feet
Input Signal Connection: (+) = J1-62, (–) = J1-43
AIC Name: D2 (DC2)
Input Reference Connection: None
External Validity Flag Connection: J1-9
AIC LSB: 2 Feet
AIC Status Mask: 0000200F
External Validity Type: Discrete Validity