Honeywell
MK VI MK VIII EGPWS Installation Design Guide
Proprietary notice on title page applies
CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-150 REV: SHEET 269
5.3.14 Category 14, Audio Output Level
The following table provides identification of the Audio Output Level Select. Each entry in the ID column corresponds to
a particular nominal alert output level selection (Max, -6 dB, -12 dB, -18dB and –24dB). The nominal “Max” output is 4
W(rms) for the 8-ohm output and 100 mW(rms) for the 600-ohm output. The Audio Output Level can be additionally
reduced by 6dB with the Mode 6 Low Volume discrete (see Category 13). The output power level will be the nominal
maximum output (4W or 100mW) reduced by the volume selection from Table 5.3.14 and the Mode 6 Low Volume
discrete.

Table 5.3.14: Audio Output Level

ID Volume Select Software
Effectivity
0Nominal (Equivalent to classic MK VI MAX) -020
1 -6 dB -020
2 -12 dB -020
3 -18 dB -020
4 -24 dB -020
5.3.15 Category 15, Undefined for this software release
The following table provides identification for a future undefined input select category. The entry in the following
undefined Type corresponds to a table that will provide detailed information on the configuration. The details for
Undefined Type #0 are not detailed.

Table 5.3.15: Undefined Type

ID Undefined
Type
Description Software
Effectivity
EGPWS
MKVI MKVIII
0 N/A -020 X X
5.3.16 Category 16, Undefined for this software release
The following table provides identification for a future undefined input select category. The entry in the following
undefined Type corresponds to a table that will provide detailed information on the configuration. The details for
Undefined Type #0 are not detailed.

Table 5.3.16: Undefined Type

ID Undefined
Type
Description Software
Effectivity
EGPWS
MKVI MKVIII
0 N/A -020 X X
5.3.17 Category 17, Undefined for this software release
The following table provides identification for a future undefined input select category. The entry in the following
undefined Type corresponds to a table that will provide detailed information on the configuration. The details for
Undefined Type #0 are not detailed.

Table 5.3.17: Undefined Type

ID Undefined
Type
Description Software
Effectivity
EGPWS
MKVI MKVIII
0 N/A -020 X X