5.3.4 Category 4, Altitude Callouts
The following table provides identification of the Altitude Callouts Menu. Each entry in the ID column corresponds to a
particular menu selection. The Altitude Callouts menu ID’s 0 through 12 consist of standard callouts. Selecting ID 0 – 12
will result in the callouts listed being enunciated.
Smart 500 activation is reflected by a “500” callout being spoken at the end of the selected callout menu sequence in the
Long Level 1 Self-Test. In addition, the Callout menu ID number and the “Smart Callout Selected” configuration
message, will both be given during level 3 Self-Test and in the RS232 Present Status display.

Table 5.3.4: Altitude Callouts

ID MENU Smart
Callout
Software
Effectivity EGPWS
Selected MKVI MK VIII
0 MINIMUMS-MINIMUMS,
“Smart 500”, 200, 100, 50, 40, 30, 20 ,10 True -020 X X
1 MINIMUMS-MINIMUMS,
“Smart 500”, 200 True -020 X X
2 MINIMUMS-MINIMUMS,
“Smart 500”, 100, 50, 40, 30, 20 ,10 True -020 X X
3 MINIMUMS-MINIMUMS,
“Smart 500” True -020 X X
41 MINIMUMS-MINIMUMS,
200, 100, 50, 40, 30, 20 ,10 False -020 X X
51 MINIMUMS-MINIMUMS,
200 False -020 X X
61 MINIMUMS-MINIMUMS,
100, 50, 40, 30, 20 ,10 False -020 X X
71 (no callouts)
False -020 X X
81 MINIMUMS-MINIMUMS
False -020 X X
9 MINIMUMS-MINIMUMS,
500, 200, 100, 50, 40, 30, 20 ,10 False -020 X X
10 MINIMUMS-MINIMUMS,
500, 200 False -020 X X
11 MINIMUMS-MINIMUMS,
500, 100, 50, 40, 30, 20 ,10 False -020 X X
12 MINIMUMS-MINIMUMS,
500 False -020 X X
13 MINIMUMS,
1000, 500, 400, 300, 200, 100, 50, 40, 30, 20, 10 False -020 X X
141 MINIMUMS-MINIMUMS,
100 False -020 X X
151 MINIMUMS-MINIMUMS,
200, 100 False -020 X X
1002 Above Field Callout “500” False -020 X X
1012 Above Field Callout “500 Above” False -020 X X
1 Compliance with TSO-C151a requires a "500" callout. These IDs cannot be used on installations requiring compliance with TSO-C151a unless
there is an alternate source of the "500" callout.
2 This ID provides Above Field Callout. Geometric altitude and runway database are used to calculate the height above field. If this ID is selected
TA&D and TCF must be enabled (MK VI and MK VIII installations cannot select Category 6 ID 2).
Note: Selecting an Altitude Callout ID without a minimums callout can be accomplished by leaving the Decision Height (DH) input discrete open.