Honeywell
MK VI MK VIII EGPWS Installation Design Guide
Proprietary notice on title page applies
CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-150 REV: SHEET 273
Signal Open Wire Threshold None
Reference Dynamic Range: None
Reference Reasonable Range: None
Scale: Roll Angle (deg) = 1 deg/deg
Input Signal Connection: (X) = J1-1, (Y) = J1-21, (Z) = J1-2
Input Reference Connection: None
AIC Name: S1 (Synchro #1)
External Validity Flag Connection: None
AIC FIFO LSB: 0.00549316°
AIC Status Mask: 0000010F
External Validity Type: None
6.1.9 Magnetic Heading, 5 Wire Synchro
The Magnetic Heading will be corrected with the internal Magnetic Variable Table.
Data Item Value
Signal Name: Magnetic Heading, 5 Wire Synchro
AIC Algorithm: 5 Wire Synchro (11.8V)
Signal Dynamic Range: ±180° Synchro Angle (15.5 VAC max)
Signal Reasonable Range: ±180°
Signal Open Wire Threshold None
Reference Dynamic Range: 17 - 34 VAC
Reference Reasonable Range: None
Scale: Mag Hdg (deg) = 1 deg/deg
Input Signal Connection: (X) = J1-22, (Y) = J1-23, (Z) = J1-3
Input Reference Connection: (H) = J1-4, (C) = J1-24
AIC Name: S2 (Synchro #2)
External Validity Flag Connection: J1-28
AIC FIFO LSB: 0.00549316°
AIC Status Mask: 0000070F
External Validity Type: Discrete Validity, +28VDC
6.1.10 Uncorrected Barometric Altitude (ADS-65)
Data Item Value
Signal Name: Uncorrected Baro Altitude, DC Voltage
AIC Algorithm: DC Absolute
Signal Dynamic Range: –5514 to +128,080 Feet
Signal Reasonable Range: –1500 to +46,000 Feet
Signal Open Wire Threshold –3000 Feet
Reference Dynamic Range: None
Reference Reasonable Range: None
Scale: Altitude (Feet) = 8333.33 Feet/VDC * Volts
Input Signal Connection: (+) = J1-62, (–) = J1-43
Input Reference Connection: None
AIC Name: D2 (DC2)
External Validity Flag Connection: J1-9
AIC LSB: 2 Feet
AIC Status Mask: 0000200F
External Validity Type: Discrete Validity
6.1.11 RT-221/300 Radio Altimeter
Data Item Value
Signal Name: Radio Altitude, RT-221/300
AIC Algorithm: DC Absolute