Honeywell
MK VI MK VIII EGPWS Installation Design Guide
Proprietary notice on title page applies
CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-150 REV: SHEET 95
3.11.5 Analog Glides lope Interface (Cat. 9 ID 0,1,5)
J1

ILS Receiver

EGPWS MK VI / MK VIII

GS Valid +28

11
+
-
Low Level
GS Valid
+28
GND
ILS
Tuned
+
-
GS Deviation 65
46
30
10
39
20

Super Flag +28V

+

-

Delayed ILS Mode

ILS Energize

GS Flag

(Low Level)

+Up
+Dn
GS Deviation
Analog-ILS-1.vsd

LOC Valid +28

48

LOC Val +28V

+
-
LOC Deviation 30
10
+L
+R
LOC Deviation

GS Inhibit (BC) +28

38

Backcourse

GS Inhibit (BC) GND

19

Backcourse

GS Valid LOC Valid ILS Tuned Deviation
Vendor Model Cat. 9
ID
SuperFlag
+28V
Low Level
Flag
SuperFlag
+28V GND GS +up
+dn
LOC +R
+L
Honeywell
KNR 6030 5 J1003-27 J1003-21
J1003-22 J1002-50 J1002-18 J1003-8
J1003-9
J1002-39
J1002-40
Honeywell
KNR 660 1P1-e
P1-q P1-k P1-T
P1-V
Honeywell
KNR 634 15 P6342-50 P6342-34
P6342-18 P6342-49 P6341-17 P6342-36
P6342-35
P6342-23
P6342-7
Honeywell
KGM-691 0 P692-W P692-S
P692-T P692-a P692-B
P692-C
Honeywell
KNR 600A 1P601-e
P601-q P601-A P601-k P601-r
P601-s
P601-m
P601-n
Collins
51RV-1, 51RV-4( ) 5 TP-27 2TP-21
TP-22 BP-50 BP-18 TP-8
TP-9
BP-39
BP-40
Collins
VIR-30, -31, -32 5 P1-17 P1-9
P1-13 P2-18 P2-40 P1-5
P1-1
P2-10
P2-13
Honeywell
VNS 41A 5 P1001-60 P1001-101 J1001-56 J1001-90
J1001-23
J1001-38
J1001-92
Honeywell
RNA-34A 5 TP-27 TP-21 BP-50 BP-18 TP-8
TP-9
BP-39
BP-40
Honeywell
KN 53 1P2-13
P2-R P2-12 P2-P
P2-14
Honeywell
KN 72
P1-2
P1-10
Honeywell
RNZ 850 5P1-A74 P1-B60
P1-B106 P1-B91 P1-B64 P1-B79
P1-B75
P1-B78
P1-B75
Honeywell
KX-155/165 1P901-U
P901-R P401-14 P401-8 P901-S
P901-T
P901-s (KX-165)
P901-k (only
NOTE: The connector pin numbers given in the Table above are to the best knowledge of Honeywell EGPWS engineering. ePlease
contact the manufacturer’s customer service to confirm your installation.
1 066-1078-00, -01, -04, -05, -10, -11, -14 and –15 only.
2 51RV-4( ) only.