| Error |
| Description |
| Code |
| |
|
|
|
COPROCESSOR COMMUNICATION ERROR – The main microprocessor is not communicating with the interface coprocessor. The interface coprocessor may be in a fault
09condition with the host or just not able to respond. This error may appear when the scanner is configured for USB or RS485 interface applications or during an attempt to update the interface software through the flash utility. The unit should be repaired at an authorized service center.
SWITCH ERROR – The switch used for volume selection or sleep mode is detected in error
11(always closed). The condition is
LASER #1 (VERTICAL) ERROR – The laser in the vertical scanning subsystem denotes a
21failure. The scanner will try three times to correct the laser operation. If the laser error persists, the vertical scanning subsystem will be shut down and this error code will remain on the Diagnostic Indicators.
LASER #2 (RIGHT HORIZONTAL) ERROR – The right laser in the horizontal scanning
22subsystem denotes a failure. The scanner will try three times to correct the laser operation. If the laser error persists, and the left horizontal laser (#3) is also in error, the horizontal scanning subsystem will be shut down and this error code will remain on the Diagnostic Indicators.
LASER #3 (LEFT HORIZONTAL) ERROR – The left laser in the horizontal scanning subsystem denotes a failure. The scanner will try three times to correct the laser operation. If
23the laser error persists, and the right horizontal laser (#2) is also in error, the horizontal scanning subsystem will be shut down and this error code will remain on the Diagnostic Indicators.
LASER #1 (VERTICAL) HIGH CURRENT WARNING – The laser in the vertical scanning
24subsystem is drawing excessive current. This could be a warning for a future total failure. Have the unit checked at an authorized service center when convenient.
LASER #2 (RIGHT HORIZONTAL) HIGH CURRENT WARNING – The laser in the vertical
25scanning subsystem is drawing excessive current. This could be a warning for a future total failure. Have the unit checked at an authorized service center when convenient.
LASER #3 (LEFT HORIZONTAL) HIGH CURRENT WARNING – The laser in the vertical
26scanning subsystem is drawing excessive current. This could be a warning for a future total failure. Have the unit checked at an authorized service center when convenient.
LASER #1 (VERTICAL) UNDERCURRENT WARNING – The laser in the vertical scanning
27subsystem is drawing too little current. The laser is probably not on. This could be the result of a loss of the required set point in memory. Have the unit checked at an authorized service center.