Scale Ready MS2421/MS2431 Models – Additional Pinout Connections

There are four additional 10-pin modular jacks located on the bottom of the of the MS2421/MS2431 scanner models that may be used for an integrated scale application and the use of a remote display.

Note: Please keep in mind that every application is unique. The use of these connections depends on the specifications of the scale’s manufacturer. The following pinouts are for reference only. If the scanner has been integrated with a scale, refer to the Scale Addendum for detailed instructions on the appropriate cable connections, communication specifications and calibration procedures required by the scale manufacturer and local Weights and Measures authorities. When connecting any combination of scale/external scale display to the MS2421/MS2431 do not exceed the following current restrictions: 12V @ 0.7A max. / 5V @ 0.2A max.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 40. Scale Ready Connector Layout

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Scale Display

 

 

 

 

 

 

 

 

 

 

 

Data In Scale

 

 

 

Scale Data In

 

 

Scale RS232 to Host

 

 

 

Data to Display

 

RS232 from the Load

 

Scale Data, Dual Cable

 

Scale to Display

from the Load

 

 

 

Cell Interface

 

 

Applications

 

 

 

Cell Interface

 

 

 

 

 

 

 

 

 

 

 

Pin

Function **

 

Pin

Function**

 

Pin

Function**

 

Pin

Function**

1

SIG1

 

1

12V

 

1

Ground

 

1

SIG1

2

SIG2

 

2

Ground

 

2

Scale RS232 TX Out

 

2

SIG2

3

SIG3

 

3

5V

 

3

Scale RS232 RX In

 

3

SIG3

4

SIG4

 

4

Ground

 

4

Scale RS232 RTS Out

 

4

SIG4

5

SIG5

 

5

RS232 TX In

 

5

Scale RS232 CTS In

 

5

SIG5

6

SIG6

 

6

RS232 RX Out

 

6

No Connect

 

6

SIG6

7

SIG7 ††

 

7

RS232 CTS In

 

7

No Connect

 

7

SIG7 ††

8

SIG8 ††

 

8

RS232 RTS Out

 

8

No Connect

 

8

SIG8 ††

9

SIG9 ††

 

9

Scale Status, TTL

 

9

No Connect

 

9

SIG9 ††

10

SIG10 ††

 

10

Scale Zero, TTL

 

10

Shield

 

10

SIG10 ††

**All signals are referenced from the MS2421/MS2431 scanner.

††The use of these pins depends upon the specifications of the scale’s manufacturer. Specifications are subject to change without notice.