Honeywell VISTA-50PUL manual Summary Of Audible Notification, Alpha Display Keypads

Models: VISTA-50P VISTA-50PUL

1 72
Download 72 pages 14.52 Kb
Page 60
Image 60
Summary Of Audible Notification

Summary Of Audible Notification

(Alpha Display Keypads)

SOUND

LOUD,

INTERRUPTED* Keypad & External

LOUD,

CONTINUOUS* Keypad & External

ONE SHORT BEEP (not repeated) Keypad only

ONE SHORT BEEP (once every 15 sec.) Keypad only

ONE BEEP (every 60 sec.) Keypad only

TWO SHORT BEEPS Keypad only

THREE SHORT

BEEPS

Keypad only

CAUSE

FIRE ALARM

BURGLARY/AUDIBLE EMERGENCY ALARM

a. SYSTEM DISARM

b. SYSTEM ARMING ATTEMPT WITH AN OPEN ZONE.

c. BYPASS VERIFY

SYSTEM IS IN TEST MODE

LOW BATTERY AT A TRANSMITTER

ARM AWAY OR MAXIMUM

a. ARM STAY OR INSTANT

b. ZONE OPENED WHILE SYSTEM IS IN CHIME MODE.

c. ENTRY WARNING**

DISPLAY

FIRE is displayed; descriptor of zone in alarm is displayed.

ALARM is displayed; descriptor of zone in alarm is also displayed.

a. DISARMED/READY TO ARM is displayed.

b. The number and descriptor of the open protection zone is displayed.

c.Numbers and descriptors of the bypassed protection zones are displayed (One beep is heard for each zone displayed). Subsequently, the following is displayed: DISARMED BYPASS Ready to Arm

Opened Zone identifications will appear.

LO BAT displayed with description of transmitter.

ARMED AWAY or ARMED MAXIMUM is displayed. Red ARMED indicator is lit.

a. ARMED STAY ZONE BYPASSED or ARMED INSTANT ZONE BYPASSED is displayed. Red ARMED indicator is lit.

b. CHIME displayed, descriptor of open protection zone will be displayed if the [4] key is pressed.

c.DISARM SYSTEM OR ALARM WILL OCCUR is displayed.

RAPID BEEPING

Keypad only

a.TROUBLE

b.AC POWER LOSS ALERT***

c.MEMORY OF ALARM

a. CHECK displayed. Descriptor of troubled protection zone is displayed.

b. AC LOSS displayed (may alternate with other displays that may be present).

c.FIRE or ALARM is displayed; descriptor of zone in alarm is displayed.

SLOW BEEPING

a. ENTRY DELAY WARNING**

a. DISARM SYSTEM OR ALARM WILL OCCUR is

Keypad only

b. EXIT DELAY WARNING

displayed. Exceeding the delay time without

 

(if programmed)

disarming causes alarm.

 

 

b. ARMED AWAY or ARMED MAXIMUM is displayed

 

 

along with You May Exit Now

*If bell is used as external sounder, fire alarm is pulsed ring; burglary/audible emergency is steady ring.

**Entry warning may consist of three short beeps or slow continuous beeping, as programmed by your installer.

***Loss of system battery power is not indicated or annunciated by the keypad (warnings are for loss of AC power only).

– 60 –

Page 60
Image 60
Honeywell VISTA-50PUL manual Summary Of Audible Notification, Alpha Display Keypads, a. DISARMED/READY TO ARM is displayed