ELECTRICAL CONNECTION
Warning - this appliance must be earthed
This appliance is designed for domestic use only. Connection to the mains supply must be made by a competant electrician, ensuring that all current regulations concerning such installations are observed.
The appliance must only be connected to a suitably rated spur point, a 3 pin 13 amp plug/socket is not suitable. A double pole switch must be provided and the circuit must have appropriate fuse protection. Further details of the power requirement of the in- dividual product will be found in the users’ instruction and on the appliance rating plate. In the case of
The wiring must be connected to the mains supply as follows:
CONNECT | TO SPUR TERMINAL |
Green & Yellow | Wire Earth Connection |
Blue Wire | Neutral Connection |
Brown Wire | Live Connection |
Note: We do not advocate the use of earth leakage devices with electric cooking applian- ces installed to spur points because of the «nuisance tripping» which may occur. You are again reminded that the appliance must be correctly earthed, the manufacturer decli- nes any responsibility for any event occurring as a result of incorrect electrical installation.
Declaration of compliance: This equipment, in the parts intended to come into con- tact with food, complies with the regulations laid down in EEC directives 89/109.
This appliance complies with directive 89/336/EEC, 73/23/EEC, 90/396/EEC and the following changes.
GAS CONNECTION
The labels on the Hob indicate the types of gas that can be used.
It is possible to use other types of gas after carrying out simple modifications.
Warning: If gas can be smelt in the vicinity of this appliance turn off the gas supply to the appliance and call the engineer directly. Do not search for a leak with a naked flame.
GB IE | 5 |